1 6/05
KPM I/KPM II STACK-MODE
ELECTRONIC SEED MONITOR
INSTALLATION INSTRUCTIONS
IS628 Rev. 6/06
Throughout these instructions the symbol and/or the words NOTE, IMPORTANT, CAUTION, WARNING
or DANGER are used to call your attention to important information. The definition of each of these terms follows:
NOTE: Indicates a special point of information or addresses a machine adjustment.
IMPORTANT: Indicates information which, if not heeded, could result in damage to the machine.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate personal injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious personal injury.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or
serious personal injury.
Before beginning installation, read completely through these instructions.
Using the shipping order and/or the Contents Listings section at the end of these instructions, check to be sure you have
all the packages needed to complete assembly.
The information used in these instructions was current at the time of printing. However, due to KINZE’s continual attempts
to improve its product, production changes may cause your planter to appear slightly different in detail. KINZE
Manufacturing, Inc. reserves the right to change specifications or design without notice and without incurring obligation
to install the same on planters previously manufactured.
Right hand (R.H.) and left hand (L.H.), as used throughout these instructions, are determined by facing in the direction
the machine will travel when in use, unless otherwise stated.
DANGER: Always install all safety lockup devices or lower machine to the ground before working under
or around the machine.
Monitor Serial No. ______________________________________________________________
Measured Pulses Per Mile/km (Radar Distance Sensor) _______________________________
Measured Pulses Per Mile/km (Magnetic Distance Sensor) ____________________________

2 6/05
The KPM I Electronic Seed Monitor Package consists of (a) a KPM I console, which is mounted on the tractor; (b) seed
tubes with sensors, one of which is installed in each planter row unit; and (c) a planter harness (junction Y-harness and/
or extension harness where applicable), to which the individual seed tube sensors connect. The primary harness, which
connects the monitor console to the planter harness, is included in the existing wiring harness on the planter.
The KPM II Stack-Mode Electronic Seed Monitor Package consists of (a) a KPM II Stack-Mode console, which is
mounted on the tractor; (b) seed tubes with sensors, one of which is installed in each planter row unit; (c) a magnetic
distance sensor, which is installed on the planter, or a radar distance sensor, which is installed on the tractor; (d) a shaft
rotation sensor kit (Models 3120, 3140, 3200, 3600, 3650, 3700 and 3800 only), which is installed on the planter drill
shafts; and (e) a planter harness (junction Y-harness and/or extension harness where applicable), to which the individual
seed tube sensors connect. The primary harness, which connects the monitor console to the planter harness, is hard
wired into the safety/warning light harness or control console harness included as standard equipment with the planter.
The software design of the KPM II Stack-Mode console allows the use of an add-on SMM console for simultaneous
viewing of the seed flow bar graphs for standard and/or Interplant
®
System rows (up to 36 rows in two sections). A total
of 72 rows may be displayed in multiple sections (rear/front, left/right or four sections). The SMM console must be used
to allow utilization of the four section feature. The SMM console is included with the KPM II Electronic Seed Monitor
Package for 24 and 36 row Model 3700 planters and all 3800 planters. It is available as a separate package for use when
3400, 3600 or 3650 planters are equipped with Interplant
®
Package rows.
The monitor is powered by the tractor battery (requires 12 volts DC).
INTRODUCTION IS628
(MTR10/MTR11) (MTR27b) (MTR27yy)
KPM II Stack-Mode
Backlit Console
KPM I Backlit Console
NOTE: If the console is not installed in the tractor at the time of planter installation, the
console must be connected to a 12 volt power source before any of the planter components
can be programmed when plugged into the planter harness. See “KPM I - Connecting Seed
Tubes” or “KPM II - Connecting SMM Console, Shaft Rotation Sensors, Seed Tubes And/
Or Radar/Magnetic Distance Sensors”.
Model 3120 Vertical Folding Planters
Model 3000/3110/3140 Stack
Folding/3200/3400/3500/3600/
3650/3700/3800 Planters
SMM Backlit Console
Radar Distance Sensor
(KPM II Only)
Magnetic (Pickup) Distance Sensor
(KPM II Only)
Shaft Rotation Sensor
(KPM II Only)
(0610102a/D10160235b/D10160235a)

3 6/05
TABLE OF CONTENTS IS628
TRACTOR COMPONENTS INSTALLATION
STEP 1. Install Console(s) ................................................................................................................................ 4
STEP 2. Connect Power ................................................................................................................................... 5
STEP 3. Install Radar Distance Sensor
(Applicable Only To KPM II Stack-Mode With Radar Distance Sensor) ............................................................ 6
PLANTER COMPONENTS INSTALLATION
STEP 1. Install Seed Tubes Into Row Units ...................................................................................................... 8
STEP 2. Install Drill Shaft Rotation Sensors
(Applicable only to Model 3120 Vertical Folding,
Model 3140 Stack Folding, Model 3200, Model 3600, Model 3650, Model 3700
and Model 3800 Planters equipped with KPM II Monitor.) ................................................................................ 10
STEP 3. Install Magnetic Distance Sensor (Applicable Only To KPM II With Magnetic Distance Sensor) ....... 12
STEP 4. Install Harnesses Between Console And Seed Tubes...................................................................... 13
Model 3000....................................................................................................................................... 14
Model 3110....................................................................................................................................... 15
Model 3120....................................................................................................................................... 16
Model 3140....................................................................................................................................... 18
Model 3200....................................................................................................................................... 20
Model 3400....................................................................................................................................... 22
Model 3500....................................................................................................................................... 23
Model 3600....................................................................................................................................... 24
Model 3650....................................................................................................................................... 26
Model 3700....................................................................................................................................... 28
Model 3800....................................................................................................................................... 30
KPM I - CONNECTING SEED TUBES
Introduction..................................................................................................................................................... 32
Step-By-Step Procedure.................................................................................................................................. 33
KPM II Stack-Mode - CONNECTING SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES
AND/OR RADAR/MAGNETIC DISTANCE SENSORS
Introduction..................................................................................................................................................... 36
Step-By-Step Procedure.................................................................................................................................. 38
(NOTE: See “Programming - Row Spacing” in the KPM II - Operation Section of this instruction.)
OPERATION
KPM I .............................................................................................................................................................. 51
KPM II Stack-Mode ......................................................................................................................................... 57
CONTENTS LISTINGS..........................................................................................................................................85

4 6/05
TRACTOR COMPONENTS INSTALLATION IS628
STEP 1. Install console(s).
Install the console on the tractor where it can be easily viewed and operated but not obstruct the operator’s view.
Using the U-shaped mounting bracket as a template, mark the location of the two bracket mounting holes. Drill two
9
/32" diameter holes.
(MTR12a/MTR12e)
CAUTION: Make sure the opposite side of the drilling surface has ample clearance and is free of wiring, etc.
Attach the mounting bracket to the mounting surface using
1
/4"-20 x
1
/2" cap screws, flat washers, lock washers and hex
nuts provided.
Secure console to mounting bracket using the knobs
supplied. Two knobs are used with the KPM I. Four
knobs are used when installing the KPM II Stack-Mode
console. Six knobs are used when installing the KPM II
Stack-Mode and SMM consoles. Position plastic wash-
ers between mounting bracket and console.
CAUTION: Use care when tightening the knobs. Tighten the knobs just enough to keep the console supported
without slipping. DO NOT over tighten knobs as this could crack the monitor console sides.
Secure Quick Reference Guide supplied in monitor package to console mounting bracket.
NOTE: A 10" monitor/radar adapter (GA9144) is supplied with the KPM II Stack-Mode console for use between
the console and radar distance sensor to adapt the monitor system to various tractor radar systems. DO NOT
CONNECT THE ADAPTER TO THE CONSOLE AT THIS TIME.
Mounting Bracket
Mounting Surface
Flat Washer, Lock
Washer And Hex Nut
Flat Washer, Lock
Washer And Hex Nut
Mounting Surface
KPM I CONSOLE INSTALLATION KPM II STACK-MODE
CONSOLE INSTALLATION KPM II STACK-MODE/SMM
CONSOLES INSTALLATION
Mounting Bracket
1
/4"-20 x
1
/2"
Cap Screw
1
/4"-20 x
1
/2"
Cap Screw
1
/4"-20 x
1
/2"
Cap Screw
NOTE: An 84" junction Y-harness (GA7853) is used to connect the SMM console to the KPM II console. DO
NOT CONNECT SMM CONSOLE TO JUNCTION Y-HARNESS UNTIL AFTER THE KPM II HAS BEEN POWERED
UP. The SMM console will go into demo mode instead of setup mode if plugged in prior to powering up the KPM II console.
022397/MTR43f
Plastic Washer
Shown With KPM II Stack- Mode And SMM Consoles Installed

5 6/05
STEP 2. Connect power.
The monitor system operates on 12VDC only. The console power lead has a 3-terminal AMP CPC female connector
which can be connected to the convenience outlet provided in late model tractors.
Use the optional power lead adapter (GA7856 supplied with KPM I or KPM II Stack-Mode consoles) if a two wire
connection is needed. Connect the “red” wire to the positive (+) battery terminal and the “black” wire to the negative
(-) battery terminal. Refer to the following illustrations for typical battery connections.
(MTR16a)
If your tractor’s battery arrangement is different than shown or if there is any question as to where to connect the power
lead, use a voltmeter to make sure you measure from 11 volts to 14 volts across the “red” and “black” leads. On tractors
using two 12 volt batteries, make sure console power leads are connected directly to the grounded battery.
NOTE: Good battery connections are essential for proper monitor operation. Make sure connections are clean
and tight. If console is connected to 6 volts or condition of 12 volt battery is less than 11 volts, a continuous
audible alarm will sound and the display on the monitor console will be fragmented when the ON/OFF switch
is depressed.
NOTE: The battery, ignition and electrical system of the tractor must be in good working order.
Secure power lead with tie straps furnished with console. DO NOT route console power lead in close proximity to
existing battery cables.
TRACTOR COMPONENTS INSTALLATION IS628
Power Lead
Power Lead
Power Lead
Power Lead
Power
Lead
Negative (-)
Ground
System24 Volt
System
12V
12V
12V 6V
6V
6V
6V
6V
6V
Vehicle
Ground
24V Starting
Relay Bank
Red
Black
Black
Red
Black
Red
Black
Red
Red
Black
Positive (+)
Ground
System
Power Lead
D091102102
Power Lead
03199703
KPM I Monitor System KPM II Stack-Mode Monitor System Power Lead Adapter (GA7856)
02239721

6 6/05
TRACTOR COMPONENTS INSTALLATION IS628
STEP 3. Install radar distance sensor. (Applicable Only To KPM II Stack-Mode With Radar Distance Sensor)
A. Install radar sensor onto mounting bracket using four
1
/4"-20 x
1
/2" cap screws and lock washers as shown below.
Be sure cut outs in bracket are facing away from the radar sensor.
(MTR33)
B. Install pipe bracket onto tractor using two
3
/8"-16 x 2" cap screws, lock washers and hex nuts. Prior to installation
of the pipe bracket onto the tractor, read the following precautions and recommendations.
Install the radar distance sensor approximately 2 feet above the ground.
The radar distance sensor should be mounted facing rearward for more physical protection to the sensor.
The radar distance sensor should not be mounted in close proximity to any major heat sources.
The face of the radar distance sensor must have an unobstructed view of the ground.
The radar distance sensor should be located where fluids do not drip directly on the unit.
The mounting should offer a minimal amount of vibration potential. Excessive vibration may cause erroneous
speed readings when the tractor is stationary.
The radar distance sensor must be mounted so it “sits on top” of the rubber vibration bushings. It should not be
mounted so it hangs from the rubber bushings.
C. Drill two holes in the mounting surface and install pipe bracket.
NOTE: Welding the bracket is not recommended in case the radar distance sensor needs to be relocated
due to vibration problems.
D. Install radar sensor/mounting bracket onto pipe bracket using two
1
/4"-20 U-bolts, flat washers, lock washers and
hex nuts. Tighten the U-bolts just enough so the radar sensor can still be tipped by hand.
Rubber Vibration Bushings
A.
1
/4"-20 x
1
/2" Cap Screws
And Lock Washers
D.
1
/4"-20 U-Bolts, Flat Washers,
Lock Washers And Hex Nuts
B.
3
/8"-16 x 2" Cap Screws,
Lock Washers And Hex Nuts

7 6/05
TRACTOR COMPONENTS INSTALLATION IS628
E. With the tractor parked on a flat surface, place a level so it is flush on the arrowed line on the radar sensor. Tip the
radar sensor until the bubble on the level is balanced at mid-line which will place the sensor at a 35° angle. Tighten
the U-bolts to secure the radar sensor mounting bracket to the pipe bracket.
(MTR34) 05319808
F. Route the cable from the radar sensor to the proper location and secure with tie straps. Use care in routing cable
to avoid sources of heat or areas that may pinch or damage the cable.
IMPORTANT: DO NOT CONNECT radar distance sensor to the monitor system at this time. See “KPM II Stack-
Mode - Connecting SMM Console, Shaft Rotation Sensors, Seed Tubes And/Or Radar/Magnetic Distance
Sensors”.
NOTE: If the monitor is using the tractor's radar for ground speed input, a customer supplied Y-cable may be
required to complete the installation.
NOTE: After installation of the radar distance sensor or any time the sensor is moved, the console must be
calibrated. See “KPM II Stack-Mode Monitor, Programming Speed” in the Operation Section of the Operator &
Parts Manual supplied with the planter.
NOTE: Excessive vibration may cause ground speed (MPH or KM/H) readings to be above zero when the tractor
is stationary. To check for vibration, start tractor engine and slowly increase engine RPM (while watching the
ground speed readout) to approximately 1800 RPM. If the ground speed readings are above zero, the radar
distance sensor must be mounted in an alternate, more stable location.
Radar Gun At 35° Angle
Level
Radar Gun
At 35° Angle
Rev. 6/06

8 6/05
PLANTER COMPONENTS INSTALLATION IS628
STEP 1. Install seed tubes into row units.
Insert seed tube w/sensor into planter row unit shank and route the sensor lead toward the planter toolbar. Position seed
tube hook over lower cross pin as illustrated below. Replace upper clevis pin through holes on upper part of seed tube
assembly. Replace hair pin clip on clevis pin. Extend sensor lead toward planter toolbar as shown on the following page.
Secure sensor lead to row unit with ties provided, allowing slack in lead for movement of parallel linkage.
Clevis Pin And Hair Pin Clip
Lower Cross
Pin
METR55b/D01250502/RU138a
Red LED (Light Emitting Diode)
Blue Connector
GA10901 Seed Tube
W/Sensor
(MECHANICAL
SEED METERING)
GA10142 Seed Tube
W/Sensor
(EDGEVAC
®
SEED METERING)
Rev. 6/06

9 6/05
NOTE: Make sure sensor lead cannot be damaged by parallel linkage movement or come in contact with drill
shaft. DO NOT CONNECT SENSOR LEAD TO PLANTER HARNESS AT THIS TIME.
PLANTER COMPONENTS INSTALLATION IS628
D102700108
Push Row Unit Sensor Lead Routing
D070799143a
Pull Row Unit Sensor Lead Routing

10 6/05
Sensor Mount
Actuator
Spring Mount
Row Unit
Support Plate
Cover
PLANTER COMPONENTS INSTALLATION IS628
09109708
A. Place top half of actuator over bottom half and snap the
sensor actuator onto the drill shaft as shown at right.
NOTE: DO NOT SLIDE the halves together.
B. Bolt plastic cover onto each side of actuator using two
No. 8-32 x 1
1
/4" stainless steel machine screws, lock
washers and nuts. See photo at right and illustration
above.
01189911
(PLTR130f/RU2c) (PLTR130g)
STEP 2. Install drill shaft rotation sensors.
(Applicable Only To Model 3120 Vertical Folding, Model 3140 Stack Folding, Model 3200, Model 3600,
Model 3650, Model 3700 And Model 3800 Planters Equipped With KPM II Stack-Mode Monitor)
Install the drill shaft rotation sensors onto the support plates between the parallel arms of the row unit as shown in the
illustrations on pages 14 through 31. In most applications the rotation sensor will be installed on the outer most row unit
on each side of the planter.
NOTE: If the row units are equipped with STYLE A frame mounted coulters, an additional support plate (left over
from frame mounted coulter installation) will have to be installed between the row units on each half of the planter
to allow installation of the drill shaft rotation sensors. If the row units are equipped with STYLE B frame mounted
coulters, a G1K364 Rotation Sensor Mounting Kit will be required.
G1K364 Rotation
Sensor Mounting Kit
(Two U-Bolts
W/Hardware And
Two Mounts)

11 6/05
PLANTER COMPONENTS INSTALLATION IS628
09109714
C. Install sensor onto mount using the two No. 10 pan
head screws, SAE washers and nuts as shown at right.
DO NOT tighten screws at this time.
E. Position assembly over row unit mounting support plate as shown.
F. Position spring mount under row unit mounting support plate and connect springs as shown above.
G. Center sensor over actuator with maximum
1
/8" gap between sensor and actuator. Tighten sensor mounting
hardware.
H. Repeat Steps A through G on opposite side of planter.
IMPORTANT: DO NOT CONNECT drill shaft rotation sensor to the planter harness at this time. The drill shaft
rotation sensors will be connected when the seed tubes are connected.
D. Install springs onto mount as shown.
09109705
01189905
Maximum
1
/8" Gap Between
Sensor And Actuator

12 6/05
PLANTER COMPONENTS INSTALLATION IS628
STEP 3. Install magnetic distance sensor. (Applicable Only To KPM II Stack-Mode With Magnetic Distance
Sensor)
See installation instruction supplied with Magnetic Distance Sensor Package (GA5606 for Model 3120 Vertical
Folding Planters and GA6147 for Model 3000, 3110 Rigid, 3140 Stack Folding, 3200, 3400, 3500, 3600, 3650, 3700 and
3800 Planters) for installation of that package.
See illustrations on pages 14 through 31 for installation locations as applicable. Secure adapter with tie straps.
IMPORTANT: DO NOT CONNECT magnetic distance sensor adapter to the planter harness at this time.
Magnetic Distance Sensor (MDS) Adapter -
Connect To Magnetic Distance Sensor Lead
Connect MDS Adapter To MDS Lead. See Instal-
lation Instruction Supplied With MDS Package.
0118991003199702
Three Pin
To Harness
Two Pin
To MDS

13 6/05
PLANTER COMPONENTS INSTALLATION IS628
C. Primary
Harness(es)
Tractor Wiring Harness
A. Planter Harness
Safety/
Warning
Light
Harness
Planter Wiring Harness
(If Applicable)
Magnetic Distance
Sensor (MDS)
DO NOT CONNECT AT
THIS TIME
STEP 4. Install harnesses between console and seed tubes.
NOTE 1: DO NOT connect seed tubes to harness during this step.
NOTE 2: When installing harnesses, take care to locate each harness where it will not be pinched, cut or
damaged by any moving parts during normal operation of the planter.
Refer to the illustrations on the following pages for additional information.
A. Lay planter harness(es) out on top of
planter frame. Each planter harness
will have
more connectors than needed
for the number of planter row units. For
example, a 12 row harness will have 16
connectors and a 16 row harness will
have 20 connectors. In addition to seed
tube connections, one connector is used
to connect the planter harness to the
monitor console on the tractor. A sec-
ond additional connector is used for
MDS hookup (If Applicable) or for use
with an optional extension harness to
add an additional length of planter har-
ness. Extra connectors may also be
used to connect the drill shaft rotation
sensors (If Applicable).
NOTE: DO NOT CONNECT harness
to any sensors at this time.
B. Connect junction Y-harness to KPM II
Stack-Mode console if SMM console is
being installed.
NOTE: DO NOT CONNECT SMM
CONSOLE TO JUNCTION Y-HAR-
NESS until entering setup procedure
to install sensors.
C. Install junction harness and/or exten-
sion harness where applicable. See the
following pages for model specific in-
stallation instructions.
NOTE: The primary harness is in-
cluded in the safety/warning light
wiring harness or tractor and planter
control console wiring harnesses.
D. Connect harnesses installed in Steps
A, B and C to each other.
E. Connect console to a 12 volt power
source. See STEP 2 in “Tractor Com-
ponents Installation”.
B. Junction Y-Harness
(If Applicable)
Monitor/Radar Adapter
DO NOT CONNECT AT
THIS TIME
E. Power
Lead
Adapter
SMM Console (SMM Console
May Not Be Applicable To All
Models)
KPM II Stack-Mode
Console
KPM II
Stack-Mode
Console
DO NOT CONNECT AT THIS TIME
(MTR43l/A9152/ELC10e/ELC10d/MTR47)
Rev. 6/06
NOTE: BE SURE planter/light wiring harness is connected to the planter monitor harness.

14 6/05
NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Neither the radar distance sensor or the magnetic
distance sensor is used with the KPM I console. Bundle and tie any unused harness connectors to the harness so they
will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
MODEL 3000 PULL TYPE PLANTER WITH INTERPLANT
®
PACKAGE
(8 Row With 7 Push Row Units Shown)
(PLTR116i)
PLANTER COMPONENTS INSTALLATION IS628
Junction Harness
Supplied With Interplant
®
Monitor Package
Planter Harness 4 Row Planter - Harness Has 7 Connectors 6 Row Planter - Harness Has 9 Connectors 8 Row Planter - Harness Has 12 Connectors
Planter Harness Supplied With Interplant
®
Monitor Package
Primary Harness Included in safety/warning light wiring harness.
MDS Adapter (If Applicable) Connected to magnetic distance sensor lead in STEP 3.
(MTR27ee/MTR47)
R1 R2 R3 R4 R5 R6 R7 R8
F1 F2 F3 F4 F5 F6 F7

15 6/05
MODEL 3110 3 POINT MOUNTED PLANTER (Rigid Frame)
(8 Row Shown)
(PLTR117h)
Planter Harness
6 Row Planter - Harness Has 9 Connectors
8 Row Planter - Harness Has 12 Connectors
Primary Harness Included in safety/warning light wiring harness.
NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Neither the radar distance sensor or the magnetic
distance sensor is used with the KPM I console. Bundle and tie any unused harness connectors to the harness so they
will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
R1 R2 R3 R4 R5 R6 R7 R8
PLANTER COMPONENTS INSTALLATION IS628
MDS Adapter
(If Applicable)
Connected to
magnetic distance
sensor lead in STEP 3.
(MTR27ee/MTR47)

16 6/05
MODEL 3120 3 POINT MOUNTED PLANTER (Vertical Folding)
(8 Row Shown)
(PLTR118a)
Planter Harness
8 Row Planter - Harness Has 12 Connectors
12 Row Planter - Harness Has 16 Connectors
Primary Harness Included in safety/warning light wiring harness.
Drill Shaft Rotation Sensor See STEP 2
NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Neither the radar distance sensor or the magnetic
distance sensor is used with the KPM I console. Bundle and tie any unused harness connectors to the harness so they
will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
R1 R2 R3 R4
PLANTER COMPONENTS INSTALLATION IS628

17 6/05
Drill Shaft Rotation Sensor
See STEP 2
MDS Adapter (If Applicable) Connected to magnetic distance sensor lead in STEP 3.
(MTR27ff/MTR47)
R5 R6 R7 R8
PLANTER COMPONENTS INSTALLATION IS628

18 6/05
MODEL 3140 3 POINT MOUNTED PLANTER (Stack Folding)
(8 Row Shown)
(PLTR119a)
Planter Harness (Wing)
8 Row Planter - Harness Has 7 Connectors
12 Row Planter - Harness Has 7 Connectors
16 Row Planter - Harness Has 7 Connectors
Planter Harness (Center Section) 8 Row Planter - Harness Has 9 Connectors 12 Row Planter - Harness Has 12 Connectors 16 Row Planter - Harness Has 16 Connectors
Extension Harness
Drill Shaft Rotation Sensor See STEP 2
NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Neither the radar distance sensor or the magnetic
distance sensor is used with the KPM I console. Bundle and tie any unused harness connectors to the harness so they
will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
R1 R2 R3 R4
PLANTER COMPONENTS INSTALLATION IS628

19 6/05
Primary Harness
Included in safety/warning light wiring harness.
Planter Harness (Wing) 8 Row Planter - Harness Has 7 Connectors 12 Row Planter - Harness Has 7 Connectors 16 Row Planter - Harness Has 7 Connectors
Extension Harness
MDS Adapter (If Applicable) Connected to magnetic distance sensor lead in STEP 3.
(MTR27ee/MTR47)
R5 R6 R7 R8
PLANTER COMPONENTS INSTALLATION IS628
Drill Shaft Rotation Sensor
See STEP 2

20 6/05
MODEL 3200 FLEX ECONO-FOLD
®
PLANTER
(12 Row Shown)
(PLTR148b/PLTR148c)
NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Neither the radar distance sensor or the magnetic
distance sensor is used with the KPM I console. Bundle and tie any unused harness connectors to the harness so they
will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
Planter Harness 8 Row Planter - Harness Has 12 Connectors 12 Row Planter - Harness Has 16 Connectors
Drill Shaft
Rotation
Sensor See STEP 2
R1 R2 R3 R4 R5 R6
PLANTER COMPONENTS INSTALLATION IS628

21 6/05
Primary Harness
Included in safety/warning light wiring harness.
Drill Shaft
Rotation Sensor See STEP 2
MDS Adapter (If Applicable) Connected to magnetic distance sensor lead in STEP 3.
(MTR27ee/MTR47)
R7 R8
R 9 R10 R11 R12
PLANTER COMPONENTS INSTALLATION IS628

22 6/05
MODEL 3400 TWIN-LINE
®
PLANTER WITH INTERPLANT
®
PACKAGE
(12 Row With 11 Push Row Units Shown)
(PLTR147i/MTR27ee/MTR47)
Planter Harness
12 Row Planter - Harness Has 16 Connectors
Planter Harness Supplied With Interplant
®
Monitor Package
NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Neither the radar distance sensor or the magnetic
distance sensor is used with the KPM I console. Bundle and tie any unused harness connectors to the harness so they
will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
Junction Y-Harness Supplied with Interplant
®
Monitor Package
MDS Adapter (If Applicable) Connected to magnetic distance sensor lead in STEP 3.
Primary Harness Included in planter wiring harness. Connect leads at valve block located on top of center frame.
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11
R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12
PLANTER COMPONENTS INSTALLATION IS628

23 6/05
MODEL 3500 TWIN-LINE
®
PLANTER WITH INTERPLANT
®
PACKAGE
(8 Row With 7 Push Row Units Shown)
(PLTR121r)
Planter Harness
6 Row Planter - Harness Has 9 Connectors
8 Row Planter - Harness Has 12 Connectors
Junction Y-Harness Supplied With Interplant
®
Monitor Package
Planter Harness Supplied With Interplant
®
Monitor
Package
Primary Harness And Extension Harness(es)
To Safety/Warning Light On L.H. Rear Planter Frame Included in safety/warning light wiring harness.
NOTE: If the
radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Neither the radar distance sensor or the magnetic
distance sensor is used with the KPM I console. Bundle and tie any unused harness connectors to the harness so they
will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
MDS Adapter (If Applicable) Connected to magnetic distance sensor lead in STEP 3.
(MTR27ee/MTR47)
F1 F2 F3 F4 F5 F6 F7
PLANTER COMPONENTS INSTALLATION IS628
R1 R2 R3 R4 R5 R6 R7 R8

24 6/05
MODEL 3600 TWIN-LINE
®
PLANTER WITH INTERPLANT
®
PACKAGE
(Model 3600 12 Row With 11 Push Row Units Shown)
(PLTR132h/PLTR132d)
Planter Harness
8 Row Planter - Harness Has 12 Connectors
12 Row Planter - Harness Has 16 Connectors
16 Row Planter - Harness Has 20 Connectors
Planter Harness Supplied With Interplant
®
Monitor Package
NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Neither the radar distance sensor or the magnetic
distance sensor is used with the KPM I console. Bundle and tie any unused harness connectors to the harness so they
will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
F1 F2 F3 F4 F5
R1 R2 R3 R4 R5 R6
PLANTER COMPONENTS INSTALLATION IS628
Drill Shaft Rotation Sensor
See STEP 2
NOTE: On 8 and 12 row sizes equipped with Interplant
®
Package,
the drill shaft rotation sensors will have to be installed on the 2nd
row in on each side of the planter to avoid interference with the
Interplant
®
Package drive.

25 6/05
MDS Adapter
(If Applicable)
Connected to
magnetic distance
sensor lead in STEP 3.
Junction Y-Harness Supplied With Interplant
®
Monitor Package
Primary Harness Included in the planter wiring harness. Connect to leads from hydraulic control harness located on rear center frame.
(MTR27ee/MTR47)
F6 F7 F8 F 9 F10 F11
R7 R8 R 9 R10 R11 R12
PLANTER COMPONENTS INSTALLATION IS628
Drill Shaft Rotation Sensor
See STEP 2
NOTE: On 8 and 12 row sizes equipped with Interplant
®
Package,
the drill shaft rotation sensors will have to be installed on the 2nd
row in on each side of the planter to avoid interference with the
Interplant
®
Package drive.

26 6/05
MODEL 3650 TWIN-LINE
®
PLANTERS WITH INTERPLANT
®
PACKAGE
(Model 3650 Bulk Fill 12 Row With 11 Push Row Units Shown)
(TWL254)
Planter Harness
12 Row Planter - Harness Has 16 Connectors
16 Row Planter - Harness Has 20 Connectors
Planter Harness Supplied With Interplant
®
Stack-Mode Monitor Package
NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to
the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
F1 F2 F3 F4 F5
R1 R2 R3 R4 R5 R6
PLANTER COMPONENTS INSTALLATION IS628
Drill Shaft Rotation Sensor
See STEP 2

27 6/05
MDS Adapter
(If Applicable)
Connected to
magnetic distance
sensor lead in STEP 3.
Junction Y-Harness Supplied With Interplant
®
Stack-Mode
Monitor Package
Primary Harness Included in the planter wiring harness. Connect to leads from hydraulic control harness located on rear center frame.
(MTR27ee/MTR47)
PLANTER COMPONENTS INSTALLATION IS628
Drill Shaft Rotation Sensor See STEP 2
F6 F7 F8 F 9 F10 F11
R7 R8 R9 R10 R11 R12

28 6/05
MODEL 3700 FRONT FOLDING PLANTER
24 Row 30" Shown
(FF94)
Planter Harness - Left Planter Wing
24 Row Planter - Harness Has 16 Connectors
36 Row Planter - Harness Has 22 Connectors
Left Draft Link
Drill Shaft Rotation Sensor See STEP 2
NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to
the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
MDS Adapter (If Applicable) Connected to magnetic distance sensor lead in STEP 3.
(MTR27ee/MTR47)
R7 R8R1 R2 R3 R4 R5 R6
PLANTER COMPONENTS INSTALLATION IS628
30' Extension Harness Supplied With Planter
Connect 30' extension harness from left draft link to harness lead
ahead of right draft link. Connect rear end of 30' extension harness to
planter harness.
R9 R10 R11 R12

29 6/05
Planter Harness - Right Planter Wing
24 Row Planter - Harness Has 16 Connectors
36 Row Planter - Harness Has 22 Connectors
Primary Harness Included in existing planter wiring harness. Connect leads at valve block located on right planter wing to planter harness supplied with monitor package.
Right Draft Link
Drill Shaft Rotation Sensor
See STEP 2
R13 R14 R15 R16 R17 R18 R19 R20
PLANTER COMPONENTS INSTALLATION IS628
R21 R22 R23 R24

30 6/05
R13 R14 R15 R16
MODEL 3800 FORWARD FOLDING PLANTER
32 Row 30" Shown
(FDW4a)
Planter Harness - Left Planter Wing
24 Row Planter - Harness Has 14 Connectors
32/36 Row Planters - Harness Has 18 Connectors
Drill Shaft Rotation Sensor See STEP 2
NOTE: If the
radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the
extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to
the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to
the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.
R7 R8R1 R2 R3 R4 R5 R6
PLANTER COMPONENTS INSTALLATION IS628
R9 R10 R11 R12
Install 15' extension
harness to connect
planter harness on left
wing to planter harness
on center section.
Connect existing planter wiring harness leads at the draft link located on left planter wing to planter harness.
Drill Shaft Rotation Sensor See STEP 2

31 6/05
Drill Shaft Rotation Sensor
See STEP 2
R17 R18 R19 R20
MDS Adapter
(If Applicable)
Connected to
magnetic distance
sensor lead in STEP 3.
(MTR27ee/MTR47)
PLANTER COMPONENTS INSTALLATION IS628
R21 R22 R23 R24 R25 R26 R27 R28 R29 R30 R31 R32
Planter Harness - Right Planter Wing
24 Row Planter - Harness Has 14 Connectors
32/36 Row Planters - Harness Has 18 Connectors
Planter Harness - Six Center Rows 24/32/36 Row Planters - Harness Has 7 Connectors
Drill Shaft Rotation Sensor See STEP 2
Connect existing planter wiring harness leads at the draft link located on right planter wing to planter harness.

32 6/05
KPM I - CONNECTING SEED TUBES IS628
MONITOR KEY FUNCTIONS
Each key press is acknowledged by the monitor with a short beep.
OK
Ends and saves the new setup during installation.
Acknowledges and silences alarms in the operation mode.
SELECT
Selects the
application mode (rear/front or left/right) at the beginning of installation setup.
Selects the active section(s) (rear, rear/front, left, right or left/right) in the operation mode.
Has no affect on a system configured to monitor only one section.
VOLUME
Pressing the key will turn the audible alarm on.
Holding the key for periods of 2 seconds increases the volume until it reaches the maximum, at which time it rolls over
to the minimum level.
ON/OFF
Powers the unit on and off.
Introduction
The KPM I electronic seed monitor system consists of a console, which is mounted on the tractor; seed tubes with
computerized sensors, one of which is installed in each planter row unit; a primary harness*, which connects the console
to the planter harness; and a planter harness (junction Y-harness and/or harness extension where applicable), to which
the individual seed tube sensors connect.
* NOTE: The primary harness, on all 3000 Series Planters, is hard-wired into the safety/warning light harness
or control console wiring harness included as standard equipment with the planter.
Seed flow for up to 36 rows, in two 18 row sections (left/right or rear/front), may be monitored with one monitor. For less
complicated applications (18 rows or less), all rows may be programmed in one section and the other section left disabled.
The monitor system is powered by the tractor battery (requires 12 volts DC). The console receives information from
each of the sensors and translates this information.
The single backlit Liquid Crystal Display (LCD) shows the active section, the number of monitored rows per section, the
relative seed rate for each row (using a bar graph display) and scrolls various alarm and warning messages when an alarm
condition exists. A continuous audible alarm will sound upon system malfunction or underflow conditions for any monitored
row. Alarms must be acknowledged by the user. Various warnings may sound the alarm or flash one or more icons.
The monitor will power down if no activity is detected within one hour. No activity means there has been no new seed flow and no operator push key input. (If applicable)
(MTR28)
NOTE: The console must be connected to a 12 volt power source.

33 6/05
KPM I - CONNECTING SEED TUBES IS628
STEP 1All the seed tubes w/sensors must be disconnected from the harness and the monitor must be off.
STEP 2Press the ON key. The monitor automatically enters the setup mode. If the monitor was accidentally powered
on with no sensors attached, the user can turn the monitor off at this point and the previous configuration is
not lost.
STEP 3
Press the SELECT key. Each time you press the SELECT key the mode will toggle between rear/front and
left/right. The selected display will be solid and the configuration not currently selected will be flashing. By
default the monitor starts in rear/front mode.
NOTE: Model 3700 (24/36 row) planters will use the left/right configuration. Models 3000, 3110, 3120,
3140, 3200, 3400, 3500, 3600/3650 and 3700 (16 row) planters will use the rear configuration only. On
Model 3000, 3400, 3500 and 3600/3650 planters equipped with Interplant
®
Packages, the rear/front
configuration will be used. When all rows can be viewed on a single display (rear), pressing the select
key has no function.
STEP 4
Press and hold the OK key to confirm the selection and continue holding until the row numbers appear on
the top display. During confirmation, the display will alternate between “NEW” and “SYS” to alert the user that
the previous configuration will be lost. With the rear/front mode selected, the monitor automatically starts with
the rear section. The REAR icon shows solid and the FRONT icon starts to flash. With the left/right mode
selected, the monitor automatically starts with the left section. The LEFT icon shows solid and the RIGHT
icon starts to flash.
SETUP FRONT REAR
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229910
FLASHING
(LEFT) (RIGHT)
FLASHING
LEFT RIGHTSETUP
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229911
(FRONT) (REAR)
FLASHING FLASHING
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229912a
SETUP FRONT REAR(LEFT) (RIGHT)
FLASHING FLASHING
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229912
SETUP FRONT REAR(LEFT) (RIGHT)
FLASHING FLASHING

34 6/05
STEP 5Plug each seed tube w/sensor into the harness in a predetermined order. Row 1 first, row 2 second and so
on up to 18 rows. When a sensor is plugged in, the corresponding row number on the LCD display will stay
solid, the monitor will chirp twice and the LED (Light Emitting Diode) on the seed tube sensor will turn on for
approximately 30 seconds to show connection is made. NOTE: Unless there is a faulty sensor, the installer
should just have to connect the sensors in the proper order without checking the monitor is acknowledging
each sensor.
STEP 6When all the seed tubes w/sensors for the current section are installed,
check to be sure the monitor displays
solid numbers for the number of sensors connected.
KPM I - CONNECTING SEED TUBES IS628
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229915
SETUP
1
REAR
1211109876543(2 13 14 15 16 17 18)
(FRONT)
FLASHING
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229916
654321
SETUP REAR
12111098 131415161718)
(FRONT)
FLASHING
(7
(METR55b)
Red LED
Blue Connector

35 6/05
STEP 7If this condition is satisfied, press and hold the OK key to save the setup for the current section. The SAVE?
icon will show followed by continuous short beeps indicating the monitor is preparing to save. The installer
has 5 seconds to decide if he wants to save the current configuration. During this time the short beeps will
sound. To complete the save, hold the OK key pressed until the word “DONE” shows on the screen followed
by a long beep and the SAVE? icon turns off. When the OK key is released the monitor will continue with the
second section installation.
NOTE: Individual seed tubes may be unplugged for special situations. An alarm will sound which can be
silenced by touching the OK key. The monitor will recognize each seed tube when reconnected.
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229920
SETUP FRONT
STEP 8Follow STEPS 5 through 7 to install the second section (FRONT or RIGHT). If no seed tubes are installed
on the second section, press and hold the OK key until the word “DONE” shows on the screen followed by
a long beep and the SAVE? icon turns off.
KPM I - CONNECTING SEED TUBES IS628
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229917
SETUP REAR
654321
SAVE?
(FRONT)
12111098 131415161718)
FLASHING
(7
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229918
SETUP REAR
654321
(FRONT)
FLASHING
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229919
SETUP FRONT SAVE?
12111098765432(1 13 14 15 16 17 18)
FLASHING

36 6/05
Introduction
The software design of the KPM II Stack-Mode console
allows the use of an add-on SMM console for simulta-
neous viewing of the seed flow bar graphs for standard
and/or Interplant
®
System rows (up to 36 rows in two
sections). A total of 72 rows may be displayed in
multiple sections (rear/front, left/right or four sections).
The SMM console must be used to allow utilization of
the four section feature.
The SMM console is included with the KPM II Stack-
Mode Electronic Seed Monitor Package for 24 and 36
row Model 3700 and all Model 3800 planters. It is
available as a separate package for use when 3400,
3600 or 3650 planters are equipped with Interplant
®
Package rows.
The monitor system is powered by the tractor battery
(requires 12 volts DC). The console receives information
from each of the sensors and translates this information.
The KPM II Stack-Mode console has two backlit Liquid
Crystal Displays (LCD). The
upper display shows the
active section, the number of monitored rows per section,
the relative seed rate for each row (using a bar graph
display) and scrolls various alarm and warning messages
when an alarm condition exists. A continuous audible
alarm will sound upon system malfunction or underflow
conditions for any monitored row. Alarms must be
acknowledged by the user. Various warnings may sound
the alarm or flash one or more icons. The
lower display is
used to display alphanumeric data such as row spacing,
units (Metric or English), speed, volume, seed population,
seed spacing, field area, total area and distance sensor
pulses per mile/kilometer.
The SMM console has one backlit Liquid Crystal Display
(LCD) which functions the same as the upper display on
the KPM II Stack-Mode console except it does not scroll
alarm and warning messages. The SMM console must
be programmed into the system before printed text will
display on the LCD.
The monitor system will power down if no activity is
detected within one hour. No activity means there has been no new seed flow and no operator push key input.
NOTE: SMM console may not be applicable to all
models.
The KPM II Stack-Mode electronic seed monitor sys-
tem consists of (a) a KPM II Stack-Mode console, which
is mounted on the tractor; (b) seed tubes with sensors,
one of which is installed in each planter row unit; (c) a
magnetic distance sensor, which is installed on the
planter, or a radar distance sensor, which is installed on
the tractor; (d) shaft rotation sensors, which are in-
stalled on the planter drill shafts; and (e) a planter
harness (junction Y-harness and/or extension harness
where applicable), to which the individual seed tube
sensors connect. The primary harness, which connects
the monitor console to the planter harness, is hard-
wired into the safety/warning light harness or control
console harness included as standard equipment with
the planter.
(MTR41d)
KPM II STACK-MODE - PROGRAMMING/CONNECTING SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

37 6/05
KPM II STACK-MODE - PROGRAMMING/CONNECTING
SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES
AND/OR RADAR/MAGNETIC DISTANCE SENSORS
MONITOR KEY FUNCTIONS
Push keys allow the user to select or change the
operating mode, the active displays or the current
configuration. Depending on the operating mode or the
current display selected, some keys are valid while
some are not. Each key press, if valid, is acknowledged
by a short beep and an action is taken. If the key press
has no action associated, the key press is considered
invalid, and the user will not get any feedback.
SELECT
Selects the
application mode (rear/front, left/right or
four sections up to a maximum of 72 rows) at the
beginning of installation in the setup mode.
Selects the
active section(s) (rear, rear/front, left,
right or left/right) in the operation mode.
Has no affect on a system configured to monitor only
one section.
While programming the monitor, the key will select
the digit to change.
SPEED
Immediately displays the current ground speed.
SCAN
If the current average population or average spacing
is displayed, this key sequentially displays the seed
population/spacing on each row.
If the display shows functions other than average
seed population or spacing, pressing SCAN will
sequentially display speed, average seed population
and average seed spacing.
Pressing a second time freezes the display on the
current row.
Pressing a third time restarts the sequential display.
SEED POPULATION/SEED SPACING Immediately displays the average seed POPULATION
and the average seed SPACING of all active rows.
Each press alternates between seed spacing and
seed population.
AREA FIELD/AREA TOTAL
Immediately displays the field or total area planted
since the field/total area was last cleared.
Each press alternates between field area and total
area.
OK
Ends and saves the new setup during installation.
Acknowledges and silences alarms in the operation
mode.
UP ARROW AND DOWN ARROW
Scrolls sequentially through the display options on
the lower LCD display.
Freezes on the current row in the scan mode.
Scrolls sequentially through the rows when the
population scan is frozen.
Used to enter programmable values in the
programming mode.
The UP and DOWN Arrow keys can be pressed at the
same time to start the CLEAR function.
SETUP ENTER/SETUP EXIT
Enters and exits the programming mode.
ON/OFF
Powers the unit on and off.
IS628

38 6/05
PROGRAMMING/CONNECTING SMM CONSOLE,
SHAFT ROTATION SENSORS, SEED TUBES AND/
OR RADAR/MAGNETIC DISTANCE SENSORS
STEP 1All sensors (including the seed tubes w/
sensors, radar, magnetic distance, SMM
console and shaft rotation sensors) must be
unplugged from the harness and/or console
and the monitor must be off.
NOTE: If the monitor detects a radar sensor but no
seed tubes at power up, it will automatically go into
AREA COUNT mode. See “Area Counter/
Speedometer Mode”.
NOTE: Disconnect magnetic distance sensor between
MDS adapter and planter harness. DO NOT disconnect
between MDS and MDS adapter.
01189910
MDS Adapter
MDS
01189909
MDS Adapter
Harness
STEP 2Press the ON key. The monitor automatically enters the setup procedure. Monitor will scroll “NO SENSOR” on top LCD of KPM II Stack- Mode console.
STEP 3The monitor automatically defaults to rear/
front. Press the SELECT key once for left/
right and twice for four sections (front right/
front left/rear right/rear left). The selected
display will be solid and the configuration not
currently selected will be flashing.
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
TOTAL
UNITS
SPEED
VOLUME
SCAN
SEED
SEED
FIELD
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP FRONT
SETUP
REAR(LEFT) (RIGHT)
Flashing Flashing
® KPM II

12060211
® SMM
KPM II STACK-MODE - PROGRAMMING/CONNECTING
SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES
AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

39 6/05
NOTE: Model 3000, 3110, 3120, 3140, 3200, 3400,
3500, 3600, 3650 and 3700 (16 row) planters select
the rear/front configuration. Model 3700 (24/36
row) and Model 3800 planters select left/right
configuration.
12060211
® SMM
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
TOTAL
UNITS
SPEED
VOLUME
SCAN
SEED
SEED
FIELD
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
® KPM II

SETUP LEFT RIGHT(FRONT) (REAR)
Flashing Flashing
NOTE: SMM console may not be applicable to all
models.
STEP 4Press and hold the OK key to confirm selection. The upper display will alternate between “NEW” and “SYS?”.
The alarm will sound four short beeps followed
by one long beep. At this point your selection
has been saved and row numbers will appear
flashing on the upper display of the KPM II.
ON
AREA
OFFEXIT
ENTER
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP FRONT
SETUP
REAR(LEFT) (RIGHT)
FLASHING FLASHING
OK
® KPM II

12060211
® SMM
NOTE: SMM console may not be applicable to all
models.
KPM II STACK-MODE - PROGRAMMING/CONNECTING SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

40 6/05
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP FRONT
SETUP
REAR(LEFT) (RIGHT)
FLASHING FLASHING
® KPM II

12060211
® SMM
NOTE: SMM console may not be applicable to all
models.
NOTE: Illustrated using rear/front configuration.
The KPM II Stack-Mode console shows LEFT in the
left/right configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR LEFT in the
four sections configuration.
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
12060211
® SMM
® KPM II

SETUP
1
REAR
12111098765432 131415161718
FRONT
FLASHING
STEP 5(If Applicable) Connect SMM console into
junction Y-harness which was installed
between the KPM II Stack-Mode console and
the primary harness. The SMM console will
show a lighted screen and KPM will show on
the lower LCD.
KPM II STACK-MODE - PROGRAMMING/CONNECTING
SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES
AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

41 6/05
STEP 6If the monitor system includes shaft rotation
sensors, these should be installed at this
time. Plug in the L.H. shaft first, then the R.H.
shaft. L.H. and R.H. is determined by facing
in the direction the machine will travel when in
use.
“LSHAFT” or “SHAFT 1” will display on the
lower LCD when the first shaft rotation sensor
is installed. “RSHAFT” or “SHAFT 2” will
display when the second shaft rotation sensor
is installed.
NOTE:
Illustrated using rear/front
configuration. The KPM II Stack-Mode
console shows LEFT in the left/right
configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR
LEFT in the four sections configuration.
01189906
NOTE: SMM console may not be applicable to all models.
MODEL 3800 PLANTERS - The first shaft
rotation sensor installed will be assigned to
the rows on the outer L.H. half of the planter
and the second shaft rotation sensor
connected will be assigned to the rows on the
inner L.H. half of the planter.
“SHAFT 1” will display on the lower LCD when
the first shaft rotation sensor is installed.
“SHAFT 2” will display when the second shaft
rotation sensor is installed. “SHAFT 3” will
display on the lower LCD when the third shaft
rotation sensor is installed on the inner R.H.
half of the planter. “SHAFT 4” will display
when the fourth shaft rotation sensor is
installed on the outer R.H. half of the planter.
KPM II STACK-MODE - PROGRAMMING/CONNECTING SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628
12060211
® SMM
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
SETUP
REAR
1
REAR
1211109876543(2 13 14 15 16 17 18)
(FRONT)
FLASHING
® KPM II

42 6/05
STEP 7Determine which row you want as number
one and plug the seed tube w/sensor into the
harness.
Continue plugging in sensors along with shaft
rotation sensors if so equipped. Row 1 first,
row 2 second and so on up to 18 rows. When
a sensor is plugged in, the corresponding row
number on the upper LCD display will stay
solid, the monitor will chirp twice and a red
LED (Light Emitting Diode) on the seed tube
sensor will turn on for approximately 30
seconds to show connection is made.
STEP 6(Continued)
NOTE: SMM console may not be applicable to all
models.
KPM II STACK-MODE - PROGRAMMING/CONNECTING SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP REAR
121110987654321(13 14 15 16 17 18)
(FRONT)
FLASHING
SETUP
REAR
® KPM II

12060211
® SMM
(METR55b)
Red LED
Blue Connector
NOTE: Illustrated using rear/front
configuration. The KPM II Stack-Mode
console shows LEFT in the left/right
configuration, REAR in the rear/front
configuration and REAR LEFT/FRONT
LEFT in the four sections configuration.

43 6/05
STEP 7(Continued)
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
1
SETUP
ROW REAR
REAR
1211109876543(2 13 14 15 16 17 18)
(FRONT)
FLASHING
Row Waiting To
Be Connected
®
Row Installed
KPM II

12060211
® SMM
KPM II STACK-MODE - PROGRAMMING/CONNECTING SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

44 6/05
STEP 8When all the seed tubes for the current section
(rear/front, left/right or four section) are
installed,
check to be sure the upper LCD on
the KPM II Stack-Mode console displays
solid numbers for the number of seed tubes connected.
Press and hold the OK key to
save the setup for the current section. The
SAVE? icon will display followed by continuous
short beeps indicating the monitor is preparing
to save. The installer has 5 seconds to decide
to save the current configuration. During this
time, four short beeps will sound followed by
a long beep and the SAVE? icon will turn off
and the word “DONE” shows on the screen.
The monitor will continue to the second section
installation (If Applicable).
NOTE:
Illustrated using rear/front
configuration. The KPM II Stack-Mode
console shows LEFT in the left/right
configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR
LEFT in the four sections configuration.
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP REARSAVE?
SAVE?SETUP
REAR
121110987654321
(131415161718)
(FRONT)
ROW
FLASHING
Row Waiting To
Be Connected
® KPM II

12060211
® SMM
KPM II STACK-MODE - PROGRAMMING/CONNECTING SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

45 6/05
STEP 8(Continued)
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP FRONT
SETUP
REAR
REAR
121110987654321
® KPM II

12060211
® SMM
NOTE: SMM console may not be applicable to all
models.
KPM II STACK-MODE - PROGRAMMING/CONNECTING SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

46 6/05
STEP 9Follow STEPS 6, 7 and 8 to install the
second, third and fourth sections (If
Applicable). If no seed tubes are installed on
additional sections, press and hold the OK
key. The word “DONE” will appear on upper
display. The alarm will sound four short beeps
followed by one long beep and the SAVE?
icon turns off. The monitor has exited the
setup mode. When you release the OK key
the upper display will scroll “WAITING
CALIBRATION”. The lower display will show
“GNDSPD” and the alarm will sound
continually until the distance sensor is
connected. See STEP 10.
NOTE: The SMM console LCD remains
blank (except the backlighted screen) until
the entire system is saved.
NOTE:
Illustrated using rear/front
configuration. The KPM II Stack-Mode
console shows LEFT in the left/right
configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR
LEFT in the four sections configuration.
The SMM console shows RIGHT in the left/
right configuration, FRONT in the front/
rear configuration and FRONT RIGHT/
REAR RIGHT in four sections
configuration.
NOTE: SMM console may not be applicable to all
models.
12060212
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
ROW FRONT
®
SMM
SETUP FRONT
12111098765432(1 13 14 15 16 17 18)
FLASHING
®
Row Waiting To
Be Connected
KPM II

KPM II STACK-MODE - PROGRAMMING/CONNECTING
SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES
AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

47 6/05
STEP 9(Continued)
NOTE: SMM console may not be applicable to all
models.
NOTE: SMM console may not be applicable to all models.
12060213
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
ROW FRONT
Row Installed
®
SMM
SETUP FRONT
1211109876543(21 131415161718)
FLASHING
®
Row Waiting To
Be Connected
KPM II

ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP.
FIELD
SELECT SPEED SCAN
SAVE?SETUP
ROW FRONT
12060214
®
SMM
SETUP
1110987654321
FRONT SAVE?
(12131415161718)
FLASHING
Rows Installed
®
Row Waiting To
Be Connected
KPM II

KPM II STACK-MODE - PROGRAMMING/CONNECTING
SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES
AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

48 6/05
STEP 10With the lower display showing “GNDSPD”,
connect the distance sensor. The monitor
will display “PICKUP” if a
magnetic distance
sensor is connected or “RADAR” if a radar
distance sensor is installed. Only one distance sensor can be connected at a time.
NOTE:
Illustrated using rear/front
configuration. The KPM II Stack-Mode
console shows LEFT in the left/right
configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR
LEFT in the four sections configuration.
The SMM console shows RIGHT in the
left/right configuration, FRONT in the rear/
front configuration and FRONT RIGHT/
REAR RIGHT in four sections
configuration.
NOTE: To connect the radar distance sensor, install
the 10" monitor/radar adapter between the console
and radar distance sensor to adapt the monitor
system to various tractor radar systems. DO NOT
CONNECT 10" MONITOR/RADAR ADAPTER PRIOR
TO THIS STEP. STEP 9(Continued)
12060215
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
FRONT
®
SMM
SETUP FRONT
1110987654321 (12 13 14 15 16 17 18)
FLASHING
® KPM II

KPM II STACK-MODE - PROGRAMMING/CONNECTING
SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES
AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

49 6/05
NOTE: To reprogram the system to monitor more or
less rows (up to the maximum of 18 per section, 72
total in four section configuration), all sensors must
be unplugged, followed by the complete setup
procedure.
NOTE: Individual seed tubes may be unplugged for
special situations. An alarm will sound which can
be silenced by touching the OK key. The monitor
will recognize the seed tube(s) when reconnected. STEP 10(Continued)
NOTE: SMM console may not be applicable to all
models.
NOTE: SMM console may not be applicable to all models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
REAR
12060216
®
SMM
®
120
110
100
90
80
70
60
% 1110987654321
12
REAR
120
110
100
90
80
70
60
% 1110987654321
FRONT
KPM II

ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
MPH
120
110
100
90
80
70
60
% 1110987654321
12060217
®
SMM
®
12
REAR
120
110
100
90
80
70
60
% 1110987654321
FRONT
KPM II

KPM II STACK-MODE - PROGRAMMING/CONNECTING
SMM CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES
AND/OR RADAR/MAGNETIC DISTANCE SENSORS
IS628

50 6/05
KPM II STACK-MODE - CONNECTING SMM IS628
CONSOLE, SHAFT ROTATION SENSORS, SEED TUBES
AND/OR RADAR/MAGNETIC DISTANCE SENSORS
NOTE: See “Programming - Row Spacing”, in the Operation
Section, for programming applicable row spacing.

51 6/05
OPERATION IS628
MONITOR KEY FUNCTIONS
Each key press is acknowledged by the monitor with a
short beep.
OK
Ends and saves the new setup during installation.
Acknowledges and silences alarms in the operation
mode.
SELECT
Selects the
application mode (rear/front or left/right)
at the beginning of installation setup.
Selects the active section(s) (rear, rear/front, left,
right or left/right) in the operation mode.
Has no affect on a system configured to monitor only
one section.
VOLUME
Pressing the key will turn the audible alarm on.
Holding the key for periods of 2 seconds increases
the volume until it reaches the maximum, at which
time it rolls over to the minimum level.
ON/OFF
Powers the unit on and off.
LCD FUNCTIONS
The monitor collects data on the planting rates from all
active rows and calculates an average. This average
will determine the 100% mark. Seed rate for each row
is then compared to the average value and the result is
displayed on the bar graph.
The information regarding each section is displayed
alternately every 5 seconds.
While operating a system
with two sections programmed, one or both sections may be selected any time. When only one section is selected, the monitor calculates the average based on the remaining active rows from that section.
STEP 1Press SELECT key once to show one section.
The flashing icon shows the section that is
not selected. The selected section is
continuously displayed on the LCD.
KPM I ELECTRONIC SEED MONITOR
The electronic seed monitor system consists of a
console, which is mounted on the tractor; seed tubes
with computerized sensors, one of which is installed in
each planter row unit; a primary harness*, which
connects the console to the planter harness; and a
planter harness (junction Y-harness and/or harness
extension where applicable), to which the individual
seed tube sensors connect.
Seed flow for up to 36 rows, in two 18 row sections (left/
right or rear/front), may be monitored with one monitor.
For less complicated applications (18 rows or less), all
rows may be programmed in one section and the other
section left disabled.
The monitor system is powered by the tractor battery
(requires 12 volts DC). The console receives information
from each of the sensors and translates this information.
The single backlit Liquid Crystal Display (LCD) shows the
active section, the number of monitored rows per section,
the relative seed rate for each row (using a bar graph
display) and scrolls various alarm and warning messages
when an alarm condition exists. A continuous audible
alarm will sound upon system malfunction or underflow
conditions for any monitored row. Alarms must be
acknowledged by the user. Various warnings may sound
the alarm or flash one or more icons.
The monitor will power down if no activity is detected
within one hour. No activity means there has been no new seed flow and no operator push key input. (If Applicable)
* NOTE: The primary harness, on all 3000 Series
Planters, is hard-wired into the safety/warning
light harness or control console harness included
as standard equipment with the planter.
(MTR28)
Monitor Key Functions ............................................... 51 LCD Functions ............................................................. 51 Changing The Audible Alarm Volume ....................... 52 Warnings And Alarms ................................................ 52 Replacing A Faulty Sensor ........................................ 53 Field Operation ............................................................ 54 Programming/Connecting Seed Tubes ..................... 54

52 6/05
OPERATION IS628
EXAMPLE: The system is setup to display
rear/front sections. Press SELECT key.
The FRONT icon will be flashing and the
REAR section will be displayed on the bar
graph. After 1 minute the FRONT icon will
stop flashing. The monitor will stay in this
REAR only display through power down
and power up. Each time the monitor is
turned on while in REAR only mode, the
FRONT icon will flash for 1 minute. Also
if seed flow is sensed in the FRONT
section while planting, the FRONT icon
will resume flashing.
STEP 2Press SELECT key again to activate both
sections.
EXAMPLE: Press SELECT key a second
time. The information regarding each
section will display alternately every 5
seconds.
For simple applications, where only one section is
programmed, the display will automatically lock on that
section. Pressing SELECT key will have no affect.
NOTE: When alternating between two sections, the
display will lock on the section containing the first
recognized alarm until the alarm is acknowledged
by pressing the OK key or the alarm condition is
removed.
CHANGING THE AUDIBLE ALARM VOLUME
STEP 1Press and hold down the VOLUME key.
STEP 2The SETUP and VOLUME icons will turn on
and the alarm will sound continuously. The
intensity of the sound will change every 2
seconds. After the maximum volume is
reached, the next change will set the volume
to minimum and will continue to get louder
every 2 seconds. When the desired volume
is reached, release the key.
WARNINGS AND ALARMS
1. System Alarms - A system alarm is activated
when the monitor detects a faulty sensor or one of
several other communication faults.
The corresponding row number starts flashing and
the alarm sounds. All segments on the
corresponding bar graph are turned off.
Pushing
the OK key to acknowledge the warning will turn the
audible alarm off. The row number will continue to
flash until the alarm condition is removed. If the
monitor detects a faulty sensor and there is no
planting activity present, the monitor will scroll
“CHECK CONNECTION”.
Another type of system alarm occurs when the
monitor detects a data communication bus error.
The three possible data communication bus errors
are:
LCD Display Error Condition
SYS HI The data communication lead
(green) has been shorted to
the power lead (white).
SYS LO The data communication lead
(green) has been shorted to
the ground lead (black).
SYS EC An internal error has been
detected.
2. Under Flow Alarms - If the seed rate for one or
more rows is less than 55% of the calculated
average, the corresponding 60% segment will stay
on, the corresponding row number starts flashing
and the alarm sounds. Pushing the OK key to
acknowledge the alarm will turn the alarm off. The
60% segment of the bar graph remains on and the
row number continues to flash until the alarm
condition is corrected.
NOTE: All alarms present within a short time before
planting stops, are frozen on the screen and the
text LOW or FAIL will display on the LCD. If the
under flow is between 0% and 10%, this warrants a
“FAIL” condition. If the under flow is between 10%
and 55%, a “LOW” condition is generated. If multiple
rows have an under flow condition, “FAIL” will
display if any one or more rows is between 0% and
10%. This allows the user to identify and fix the
problem rows.

53 6/05
OPERATION IS628
7. Seed Counting Sensor Too Dirty Warning - After
the seed counting sensors end their internal self-
calibration, the monitor may detect one or more
sensors are either too dirty or blocked. If the monitor
detects planting or movement, the corresponding
bar graph remains flashing. The monitor will display
“CLEAN SENSORS” on the LCD if no movement or
planting is detected, prompting the user to clean
the tubes. If the tubes are dirty, they will still show
seed flow with less accuracy. If the tubes are
blocked the user will get an alarm as soon as
planting starts. The corresponding bar graph will
remain flashing until the problem is corrected and
the monitor is powered down and then powered
back up.
8. Low Battery Warning - The monitor is constantly
monitoring its input voltage to quickly detect low
power conditions. If the monitor detects that the
input voltage has dropped below 11.0V, it will
display “LOW POWER” on the LCD, provided that
the monitor does not detect planting.
NOTE: After the alarms have been acknowledged
and if the alarm condition is still present, the LCD
will continue to display the alarm condition.
REPLACING A FAULTY SENSOR
To replace a faulty sensor; (a) disconnect the faulty
sensor and check the monitor to be sure the correct
sensor was disconnected, (b)
turn the monitor off, (c)
after a few seconds, turn the monitor back on and (d)
plug in the replacement sensor. The monitor will chirp
twice to acknowledge the new sensor was learned and
saved.
To replace more than one faulty sensor, proceed as
stated above beginning with the lowest numbered row
in the rear or left section and continue to replace
sensors in increasing order. Then move on to the front
or right section and continue in ascending row number
order.
NOTE: If the monitor is not turned off and then on,
the replacement sensor(s) will be ignored until the
next power on, at which point they will be randomly
learned by the monitor.
NOTE: This warning will not trigger unless a
minimum time of continuous planting has passed.
NOTE: If all the rows show a seed rate of zero, the
condition will not generate an alarm. It will be
assumed the planter has stopped. The row numbers
and the bottom 60% segment will remain on for all
selected rows.
3. Multiple Alarms - If more than one alarm condition
occurs at the same time, pushing the OK key will
acknowledge all alarms that are currently displayed.
For example, if one row on the front and one row on
the rear are alarming, pushing the OK key will only
acknowledge one of them. However, if there are
two alarms on the front, both alarms would be
acknowledged with one push of the OK key.
4. Section Not Selected Warning - If the monitor
was programmed for two sections and only one is
currently selected for display (by pressing the
SELECT key), the icon of the disabled section will
flash for a period of 1 minute, then turn off at each
power up. If seed flow is sensed in the disabled
section, the icon for that section (front, left or right)
will begin to flash.
5. Seed Planting Stopped Warning - When the
monitor detects no seed flow on all rows, the
monitor will emit 3 short beeps to alert the user. This
warning will occur each time the planter is stopped,
each time the planter is raised at the end of a row
or if the mechanical drive fails while planting.
NOTE: This warning will not trigger unless a
minimum time of continuous planting has passed.
6. Seed Counting Sensor In Calibration Warning -
All seed counting sensors run a self-calibration
sequence on power up. While in calibration the
bottom segment of each corresponding bar graph
will flash if the monitor detects movement or planting
activity. If the monitor does not detect this, the
message “WAIT CALIBRATION” will be scrolled.

54 6/05
OPERATION IS628
FIELD OPERATION
(MTR28e/MTR28c/MTR28d/MTR28b)
Press the ON/OFF key to turn the monitor
on and off.
Information regarding each section is dis-
played alternately every 5 seconds.
REAR/FRONT CONFIGURATION
Press the SELECT key once to show
REAR section only.
Press the SELECT key a second time to
return to each section being displayed
alternately every 5 seconds.
Press the SELECT key a third time to
show REAR section only again.
LEFT/RIGHT CONFIGURATION
Press the SELECT key once to show
LEFT section only.
Press the SELECT key a second time to
show RIGHT section only.
Press the SELECT key a third time to
return to each section being displayed
alternately every 5 seconds.
NOTE: SELECT key has no function when only a
single section is being used.
Press the VOLUME key to increase or
decrease volume. See “Changing The
Audible Alarm Volume”.
Press the OK key to silence alarms. See
“Warnings And Alarms”.
SETUP FRONT REAR
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229910
FLASHING
(LEFT) (RIGHT)
FLASHING
LEFT RIGHTSETUP
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229911
(FRONT) (REAR)
FLASHING FLASHING
PROGRAMMING/CONNECTING SEED TUBES
STEP 1All the seed tubes w/sensors must be
disconnected from the harness and the
monitor must be off.
STEP 2Press the ON key. The monitor automatically
enters the setup procedure. If the monitor
was accidentally powered on with no sensors
attached, the user can turn the monitor off at
this point and the previous configuration is
not lost.
STEP 3
Press the SELECT key. Each time you press
the SELECT key the mode will toggle between
rear/front and left/right. The selected display
will be solid and the configuration not currently
selected will be flashing. By default the
monitor starts in rear/front mode.
NOTE: Model 3700 (24/36 row) planters will use the left/right configuration. Models 3000, 3110, 3120, 3140, 3200, 3400, 3500, 3600/3650 and 3700 (16 row) planters will use the rear/front configuration only. When all rows can be viewed on a single display (rear), pressing the select key has no function.

55 6/05
OPERATION IS628
STEP 5Plug each seed tube w/sensor into the
harness in a predetermined order. Row 1
first, row 2 second and so on up to 18 rows.
When a sensor is plugged in, the
corresponding row number on the LCD
display will stay solid, the monitor will chirp
twice and the LED (Light Emitting Diode) on
the seed tube sensor will turn on for
approximately 30 seconds to show
connection is made. NOTE: Unless there is a
faulty sensor, the installer should just have to
connect the sensors in the proper order without
checking the monitor is acknowledging each
sensor.
STEP 6When all the seed tubes w/sensors for the
current section are installed,
check to be
sure the monitor displays solid numbers for the number of sensors connected.
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229915
SETUP
1
REAR
1211109876543(2 13 14 15 16 17 18)
(FRONT)
FLASHING
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229916
654321
SETUP REAR
12111098 131415161718)
(FRONT)
FLASHING
(7
STEP 4Press and hold the OK key to confirm the
selection and continue holding until the row
numbers appear on the display. During
confirmation, the display will alternate between
“NEW” and “SYS” to alert the user that the
previous configuration will be lost. With the
rear/front mode selected, the monitor
automatically starts with the rear section. The
REAR icon shows solid and the FRONT icon
starts to flash. With the left/right mode
selected, the monitor automatically starts with
the left section. The LEFT icon shows solid
and the RIGHT icon starts to flash.
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229912a
SETUP FRONT REAR(LEFT) (RIGHT)
FLASHING FLASHING
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229912
SETUP FRONT REAR(LEFT) (RIGHT)
FLASHING FLASHING

56 6/05
OPERATION IS628
STEP 7If this condition is satisfied, press and hold
the OK key to save the setup for the current
section. The SAVE? icon will show followed
by continuous short beeps indicating the
monitor is preparing to save. The installer
has 5 seconds to decide if he wants to save
the current configuration. During this time
the short beeps will sound. To complete the
save, hold the OK key pressed until the word
“DONE” shows on the screen followed by a
long beep and the SAVE? icon turns off.
When the OK key is released the monitor will
continue with the second section installation.
NOTE: Individual seed tubes may be unplugged for
special situations. An alarm will sound which can
be silenced by touching the OK key. The monitor
will recognize each seed tube when reconnected.
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229920
SETUP FRONT
STEP 8Follow STEPS 5 through 7 to install the
second section. If no seed tubes are installed
on the second section, press and hold the
OK key until the word “DONE” shows on the
screen followed by a long beep and the
SAVE? icon turns off.
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229917
SETUP REAR
654321
SAVE?
(FRONT)
12111098 131415161718)
FLASHING
(7
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229918
SETUP REAR
654321
(FRONT)
FLASHING
ON
OFF
OK
VOLUME
®
KPM I
SELECT
01229919
SETUP FRONT SAVE?
12111098765432(1 13 14 15 16 17 18)
FLASHING

57 6/05
OPERATION IS628
KPM II STACK-MODE ELECTRONIC
SEED MONITOR
NOTE: SMM console may not be applicable to all
models.
The KPM II Stack-Mode electronic seed monitor sys-
tem consists of (a) a KPM II Stack-Mode console, which
is mounted on the tractor; (b) seed tubes with sensors,
one of which is installed in each planter row unit; (c) a
magnetic distance sensor, which is installed on the
planter, or a radar distance sensor, which is installed on
the tractor; (d) shaft rotation sensors, which are in-
stalled on the planter drill shafts; and (e) a planter
harness (junction Y-harness and/or extension harness
where applicable), to which the individual seed tube
sensors connect. The primary harness, which connects
the monitor console to the planter harness, is hard-
wired into the safety/warning light harness or control
console harness included as standard equipment with
the planter.
The software design of the KPM II Stack-Mode console
allows the use of an add-on SMM console for simulta-
neous viewing of the seed flow bar graphs for standard
and/or Interplant
®
System rows (up to 36 rows in two
sections). A total of 72 rows may be displayed in
(MTR41e)
Monitor Key Functions ............................................... 58 Upper LCD Functions ................................................. 69 Lower LCD Functions ................................................. 60 Programming
Changing The Audible Alarm Volume ................ 62
Units (Metric Or English) ..................................... 63
Row Spacing ......................................................... 63
Speed ..................................................................... 65
Clearing Total Area .............................................. 66
Area Counter/Speedometer Mode ............................. 67
Warnings And Alarms ................................................ 67
Replacing A Faulty Sensor ........................................ 68
Field Operation ............................................................ 69
Clearing Field Area ..................................................... 70
Programming/Connecting SMM Console,
Shaft Rotation Sensors, Seed Tubes And/Or
Radar/Magnetic Distance Sensors ............................ 71
Row-By-Row Alarm Level Setting ............................. 83
multiple sections (rear/front, left/right or four sections).
The SMM console must be used to allow utilization of
the four section feature.
The SMM console is included with the KPM II Stack-
Mode Electronic Seed Monitor Package for 24 and 36
row Model 3700 planters and all Model 3800 planters.
It is available as a separate package for use when 3400,
3600 or 3650 planters are equipped with Interplant
®
Package rows.
The monitor system is powered by the tractor battery
(requires 12 volts DC). The console receives information
from each of the sensors and translates this information.
The KPM II Stack-Mode console has two backlit Liquid
Crystal Displays (LCD). The
upper display shows the
active section, the number of monitored rows per section,
the relative seed rate for each row (using a bar graph
display) and scrolls various alarm and warning messages
when an alarm condition exists. A continuous audible
alarm will sound upon system malfunction or underflow
conditions for any monitored row. Alarms must be
acknowledged by the user. Various warnings may sound
the alarm or flash one or more icons. The
lower display is
used to display alphanumeric data such as row spacing,
units (Metric or English), speed, volume, seed population,
seed spacing, field area, total area and distance sensor
pulses per mile/kilometer.
The SMM console has one backlit Liquid Crystal Display
(LCD) which functions the same as the upper display on
the KPM II Stack-Mode console except it does not scroll
alarm and warning messages. The SMM console must
be programmed into the system before printed text will
display on the LCD.
The monitor system will power down if no activity is
detected within one hour. No activity means there has been no new seed flow and no operator push key input.

58 6/05
OPERATION IS628
MONITOR KEY FUNCTIONS
Push keys allow the user to select or change the
operating mode, the active displays or the current
configuration. Depending on the operating mode or the
current display selected, some keys are valid while
some are not. Each key press, if valid, is acknowledged
by a short beep and an action is taken. If the key press
has no action associated, the key press is considered
invalid, and the user will not get any feedback.
SELECT
Selects the
application mode (rear/front, left/right or
four sections up to a maximum of 72 rows) at the
beginning of installation in the setup mode.
Selects the
active section(s) (rear, rear/front, left,
right or left/right) in the operation mode.
Has no affect on a system configured to monitor only
one section.
While programming the monitor, the key will select
the digit to change.
SPEED
Immediately displays the current ground speed.
SCAN
If the current average population or average spacing
is displayed, this key sequentially displays the seed
population/spacing on each row.
If the display shows functions other than average
seed population or spacing, pressing SCAN will
sequentially display speed, average seed population
and average seed spacing.
Pressing a second time freezes the display on the
current row.
Pressing a third time restarts the sequential display.
SEED POPULATION/SEED SPACING Immediately displays the average seed POPULATION
and the average seed SPACING of all active rows.
Each press alternates between seed spacing and
seed population.
AREA FIELD/AREA TOTAL
Immediately displays the field or total area planted
since the field/total area was last cleared.
Each press alternates between field area and total
area.
OK
Ends and saves the new setup during installation.
Acknowledges and silences alarms in the operation
mode.
UP ARROW AND DOWN ARROW
Scrolls sequentially through the display options on
the lower LCD display.
Freezes on the current row in the scan mode.
Scrolls sequentially through the rows when the
population scan is frozen.
Used to enter programmable values in the
programming mode.
The UP and DOWN Arrow keys can be pressed at the
same time to start the CLEAR function.
SETUP ENTER/SETUP EXIT
Enters and exits the programming mode.
ON/OFF
Powers the unit on and off.

59 6/05
OPERATION IS628
(MTR29h)
STEP 1Press SELECT key once to show one section.
The flashing icon shows the section that is
not selected. The selected section icon is
continuously displayed on the LCD.
EXAMPLE: The system is setup to display
rear section on KPM II Stack-Mode
console and front section on SMM
console. Press SELECT key. The FRONT
icon will be flashing and the REAR section
will be displayed on the bar graph. The
SMM console is only backlit. After 1 minute
the front row icon will stop flashing. The
monitor will stay in this REAR only display
through power down and power up. Each
time the monitor is turned on while in
REAR only mode, the FRONT icon will
flash for 1 minute.
If seed flow is sensed in the FRONT
section while planting, the FRONT icon
will resume flashing.
When the front section is disabled, the
row spacing will automatically double to
maintain the proper implement width in
the monitor. A 23 or 24 row 15"
configuration changes to a 12 row 30"
configuration with a touch of the SELECT
key.
STEP 2Press SELECT key again to activate both
sections.
For simple applications, where only one section is
programmed, the display will automatically lock on that
section. Pressing the SELECT key will have no affect.
NOTE: When alternating between two sections, the
display will lock on the section containing the first
recognized alarm until the alarm is acknowledged
by pressing the OK key or the alarm condition is
removed.
UPPER LCD FUNCTIONS
The monitor collects data on the planting rates from all
active rows and calculates an average. This average
will determine the 100% mark. Seed rate for each row
is then compared to the average value and the result is
displayed on the bar graph.
With only the KPM II Stack-Mode console programmed
into the system, the information regarding each section
is displayed alternately every 5 seconds.
While operating
a system with two sections programmed, one or both sections may be selected any time. When only one section is selected, the monitor calculates the average based on the remaining active rows from that section.
With the SMM console programmed into the system,
two sections are viewed at the same time. If the system
configuration is for four sections, the display will alternate
every 5 seconds between a pair of sections. The select
key will lock the display on rear sections.
The SMM
console shows RIGHT in the left/right configuration, FRONT in the rear/front configuration and FRONT RIGHT/REAR RIGHT in four sections configuration.
The KPM II Stack-Mode console shows LEFT in the left/ right configuration, REAR in the rear/front configuration and FRONT LEFT/REAR LEFT in four sections configuration.

60 6/05
OPERATION IS628
LOWER LCD FUNCTIONS
(MTR29g)
The UP and DOWN arrow keys will sequentially
change what is being displayed on the lower LCD.
Pressing the UP or DOWN arrow keys will move the
arrow head icon (on the left and right hand side of
the display) to another item. For example, if the
arrow icon is pointing to SPEED, ground speed will
be displayed on the LCD. Pressing the UP arrow
key will move the icon to UNITS. The display will
change to display all the icons used to represent the
current (English or Metric) measurement system.

The shortcut keys SPEED, SEED POPULATION/
SPACING and AREA FIELD/TOTAL allow direct
access to their respective displays. For example,
no matter what is currently being displayed on the
lower LCD, pressing the SPEED key will change
the display to the current speed. Pressing the
SEED POPULATION/SPACING or AREA FIELD/
TOTAL keys will alternate between the two functions
assigned to those keys.

Pressing the SCAN key while displaying seed
spacing or population will cause a sequential display
of each individual row. Pressing the SCAN key a
second time will freeze the display on the currently
displayed row. The UP or DOWN arrow keys can be
used to change the currently displayed row. Pressing
the SCAN key will restart the automatic advancing
of the scan function.

Pressing the SCAN key while displaying speed will
cause a sequential display of speed, average planter
population and average seed spacing. Pressing the
SCAN key a second time will freeze the display on
the currently displayed reading.
ROW SPACING
Press the arrow keys to ROW SPACING to display the
current spacing between rows in inches or centimeters.
The ROW SPACING icons turn on, displaying a 3 digit,
one decimal place format. In the area count mode, this
function displays the implement width in feet or meters,
using a 3 digit, no decimal places format.
UNITS
Press the arrow keys to UNITS to display all the icons
from the currently selected English or Metric
measurement system. For the English system, the
icons are: INCH, MPH, FT, ACRE and MILE. For the
Metric system, the icons are: M, KM/H and Ha.
SPEED
Press the SPEED key to display the current speed in
MPH or KM/H, using a 3 digit, one decimal place format.
VOLUME
Press the arrow keys to VOLUME to display the presently
selected audible alarm volume. The SPEAKER icon
turns on.
SCAN
Press the SCAN key to display the
seed spacing or
seed population (see Steps 1-3 following) of each individual row. (1)Pressing the SCAN key while displaying any other function will cause the monitor to sequentially display speed, average seed population and average seed spacing. (2)Pressing the SCAN key a second time will freeze the display. (3)Pressing the SCAN key a third time restarts the sequential display. The UP and DOWN arrow keys can be used to change the current display.
Rev. 4/06

61 6/05
OPERATION IS628
FIELD AREA/TOTAL AREA
Each AREA FIELD/TOTAL key press alternates
between field area and total area.
Field area displays the total number of acres or hectares
using a 6 digit, one decimal place format.
NOTE: When FIELD AREA is selected, the UP or
DOWN key must be held in slightly longer than
normal so the monitor will not mistake this action
with a CLEAR, which consists of the UP and DOWN
arrow keys pressed simultaneously. A beep will
sound when the function activates.
Total area displays the total number of acres or hectares
using a 6 digit, one decimal place format. The total area
counter updates every time the field area counter
increments. Clearing the total area counter will also
clear the field area counter.
When the monitor is programmed as a rear only or
rear/front configuration and shaft rotation sensors
are installed, pressing the UP arrow to move beyond
row spacing lights an arrow on an unlabeled area
above ROW SPACING. This is the automatically set
division line between the L.H. shaft sensor and the
R.H. shaft sensor. The display shows the first row on
the rear section and the front section assigned to the
R.H. shaft rotation sensor.
EXAMPLE: On a 12 Row 30" planter with
Interplant
®
Package, the display would appear as
follows:
092597-21
THIS DISPLAY IS NOT ACCESSIBLE ON LEFT/
RIGHT CONFIGURATIONS OR SYSTEMS
WITHOUT SHAFT ROTATION SENSORS.
SEED POPULATION/SEED SPACING
Each SEED POP/SPACING key press alternates
between seed population and seed spacing.
Seed population displays the average number of seeds or the row average number of seeds per acre or seeds per hectare for all the active rows. The average is displayed using a 6 digits, no decimal places format. The AVERAGE POPULATION icon will turn on. When in the scan mode, the
scan arrow and SCAN ROW
POPULATION will appear. The ROW number icon and
the current row will be displayed on the left and the
population will be displayed on the right in 1000’s using
3 digits, one decimal place (e.g. 32.9 means 32,900).
When in scan freeze mode, the
scan arrow and ROW
POPULATION will turn on (scan arrow may be flashing).
The UP and DOWN keys may be used to lock on the
desired row.
Seed spacing displays the average distance or the row average distance between seeds for all active rows in inches per seed or centimeters per seed using a 3 digit, one decimal place format. When the average is displayed the AVERAGE SPACING icons are turned on. When in the scan mode, the
scan arrow and SCAN ROW
SPACING icons will appear. The ROW number icon
and the current row will be displayed on the left and the
spacing will be displayed on the right. The display will
sequence to the next row every 5 seconds. When in
scan freeze mode, the
scan arrow and SPACING will
turn on (scan arrow may be flashing). The UP and
DOWN keys may be used to lock on the desired row.

62 6/05
OPERATION IS628
STEP 4To exit without saving, press and release the
OK key. The monitor will restore the lower
LCD to show the setting of the item, and the
arrow icon will flash, allowing the user to
select another item to program.
To exit and save, press and hold the OK key. The monitor will emit several short beeps and SAVE? icon is turned on. After a short time a long beep is heard, and the lower LCD will display the word “DONE”. Release the OK key. If the OK key is released BEFORE the word “DONE” is displayed, the changes WILL NOT BE SAVED. The word “DONE” MUST be displayed in order for the save to have occurred.
NOTE: The programming mode may be exited at
any time, by pressing the SETUP key. Pressing this
key will return the monitor to its normal operation.
All items changed and saved will come into effect
immediately. Any items changed, but not saved will
revert to the original programmed value.
PROGRAMMING - Changing The Audible
Alarm Volume
STEP 1To enter the programming mode, press and
hold the SETUP key. The monitor will emit
several short beeps, followed by a long beep.
On the lower LCD, the SETUP icon turns on
and the arrow head icon will flash, indicating
that the user can select an item to program.
NOTE: The monitor must be in a programmable
function (row spacing, units, speed, volume or
area) to enter setup. The monitor will not enter
setup in seed population or seed spacing.
STEP 2Press the UP or DOWN arrow keys to move
the flashing arrow to VOLUME. As the arrow
icon moves, the lower LCD will display the
current setting of the item selected.
STEP 3Press the OK key and the flashing arrow
becomes solid and the audible alarm will
sound.
NOTE: The lower LCD will display the current volume
and the SPEAKER icon is turned on. Settings are
from 0 to 9.
Use the UP or DOWN arrow keys to change
the setting. With every UP arrow key push,
the alarm will increment by one step between
the minimum and the maximum. If the
maximum level (9) is reached the volume
rolls over to the minimum level (0).
Pressing the DOWN arrow key lowers the
volume until the minimum level (0) is reached,
at which point the volume rolls over to the
maximum level (9).

63 6/05
OPERATION IS628
PROGRAMMING - Units (Metric Or English)
STEP 1To enter the programming mode, press and
hold the SETUP key. The monitor will emit
several short beeps, followed by a long
beep. On the lower LCD, the SETUP icon
turns on and the arrow head icon will flash,
indicating that the user can select an item to
program.
NOTE: The monitor must be in a programmable
function (row spacing, units, speed, volume or
area) to enter setup. The monitor will not enter
setup in seed population or seed spacing.
STEP 2Press the UP or DOWN arrow keys to move
the flashing arrow to UNITS. As the arrow
icon moves, the lower LCD will display the
current setting of the item selected.
STEP 3Press the OK key and the flashing arrow
becomes solid and the audible alarm will
sound.
NOTE: The lower LCD will alternately display all
Metric icons or all English icons, indicating the
Metric or English mode respectively.
Use the UP or DOWN arrow keys to change
the setting.
STEP 4
To exit without saving, press and release the
OK key. The monitor will restore the lower
LCD to show the setting of the item, and the
arrow icon will flash, allowing the user to
select another item to program.
To exit and save, press and hold the OK key. The monitor will emit several short beeps and SAVE? icon is turned on. After a short time a long beep is heard, and the lower LCD will display the word “DONE”. Release the OK key. If the OK key is released BEFORE the word “DONE” is displayed, the changes WILL NOT BE SAVED. The word “DONE” MUST be displayed in order for the save to have occurred.
NOTE: The programming mode may be exited at
any time, by pressing the SETUP key. Pressing this
key will return the monitor to its normal operation.
All items changed and saved will come into effect
immediately. Any items changed, but not saved
will revert to the original programmed value.
PROGRAMMING - Row Spacing
STEP 1Prior to entering the programming mode, the
application mode (rear/front, left/right or four
sections) must be active. If the monitor is
programmed in a rear/front configuration,
both sections will be active (alternating every
5 seconds if the SMM console is not used).
You can then set the row spacing to the
Interplant
®
System row spacing.
EXAMPLE: On a 12 Row 30" with Interplant
®
Package set the row spacing to 15.0 with
front active.
When the monitor is in normal field operation
mode, disabling the front section will
automatically change the row spacing to 30".
STEP 2To enter the programming mode, press and
hold the SETUP key. The monitor will emit
several short beeps, followed by a long
beep. On the lower LCD, the SETUP icon
turns on and the arrow head icon will flash,
indicating that the user can select an item to
program.
NOTE: The monitor must be in a programmable
function (row spacing, units, speed, volume or
area) to enter setup. The monitor will not enter
setup in seed population or seed spacing.
STEP 3Press the UP or DOWN arrow keys to move
the flashing arrow to ROW SPACING. As
the arrow icon moves, the lower LCD will
display the current setting of the item
selected.
STEP 4Press the OK key and the flashing arrow
becomes solid and the audible alarm will
sound.
NOTE: The lower LCD will display the current row
spacing (in inches or centimeters) and ROW
SPACING icon is turned on.
The least significant digit of the displayed
value will be blinking.
This value can be changed by pressing
either the UP or DOWN arrow keys.
Once this digit is correct, press the MODE
SELECT key and the blinking digit will move
to the next significant digit, where the process
can be repeated.

64 6/05
OPERATION IS628
NOTE: The monitor limits the entry of row spacing
to a minimum of 10.0 inches (25.4 cm) and to a
maximum of 99.9 inches (253.7 cm). If the monitor
is configured to a rear/front configuration, the
limits change to a minimum of 5.0 inches (12.7 cm)
and a maximum of 49.9 inches (126.8 cm).
STEP 5
To exit without saving, press and release the
OK key. The monitor will restore the lower
LCD to show the setting of the item and the
arrow icon will flash, allowing the user to
select another item to program.
To exit and save, press and hold the OK key. The monitor will emit several short beeps and SAVE? icon is turned on. After a short time a long beep is heard, and the lower LCD will display the word “DONE”. Release the OK key. If the OK key is released BEFORE the word “DONE” is displayed, the changes WILL NOT BE SAVED. The word “DONE” MUST be displayed in order for the save to have occurred.
To exit setup mode, press the SETUP key.
NOTE: The programming mode may be exited at
any time, by pressing the SETUP key. Pressing this
key will return the monitor to its normal operation.
All items changed and saved will come into effect
immediately. Any items changed, but not saved
will revert to the original programmed value.

65 6/05
OPERATION IS628
PROGRAMMING - Speed
STEP 1To enter the programming mode, press and
hold the SETUP key. The monitor will emit
several short beeps, followed by a long
beep. On the lower LCD, the SETUP icon
turns on and the arrow head icon will flash,
indicating that the user can select an item to
program.
NOTE: The monitor must be in a programmable
function (row spacing, units, speed, volume or
area) to enter setup. The monitor will not enter
setup in seed population or seed spacing.
STEP 2Press the UP or DOWN arrow keys to move
the flashing arrow to SPEED. As the arrow
icon moves, the lower LCD will display the
current setting of the item selected.
STEP 3Press the OK key and the flashing arrow
becomes solid and the audible alarm will
sound. The R.H. digit on the display will be
blinking.
The speed constant is used to record how
many pulses are generated per mile (or
kilometer) from the ground speed sensor.
The lower LCD will display the current pulses
per mile (or kilometer) using a 6 digit, no
decimal place format. The PULSES per MILE
(or PULSES per KM) icons are turned on.
NOTE: It is highly recommended that a field
calibration be done to establish the PPM/PPKM
(Pulses Per Mile/Kilometer) number on a new
machine installation. Several factors can affect
this value such as wheel slip on the magnetic
distance sensor, mounting angle and height on the
radar distance sensor, etc. IT IS NOT UNCOMMON
FOR THE SPEED ON THE MONITOR TO VARY
SLIGHTLY FROM THE TRACTOR SPEEDOMETER.
Adjusting the PPM/PPKM in the monitor to make
the speed agree can cause serious errors in acre/
hectare counts and population readings.
Do field
checks to verify populations and seed spacings.
NOTE: On new system installations, the monitor
will default to 500 PPM (310 PPKM). This will have
to be changed to obtain accurate readings from the
monitor.
In field conditions, measure 330 feet (
1
/16
mile) or 100 meters, depending on the unit of
measurement selected.
Pull the tractor up to the starting line.
Press the UP and DOWN arrow keys at the
same time and hold them down until the
CLEAR? icon is displayed and the monitor
beeps several times. When the data is
actually cleared, the monitor will emit a long
beep and the number of pulses is cleared.
NOTE: If the PPM/PPKM number starts to
count pulses with the tractor not moving,
check the radar for vibration or other
kinds of interference.
Drive the tractor for 330 feet (
1
/16 mile) or
100 meters and stop.
The monitor will count the number of pulses
and display them.
STEP 4
To exit without saving, press and release the
OK key. The monitor will restore the lower
LCD to show the previous setting of the item,
and the arrow icon will flash, allowing the
user to select another item to program.
To exit and save, press and hold the OK key. The monitor will emit several short beeps and SAVE? icon is turned on. After a short time a long beep is heard, and the lower LCD will display the word “DONE”. Release the OK key. If the OK key is released BEFORE the word “DONE” is displayed, the changes WILL NOT BE SAVED. The word “DONE” MUST be displayed in order for the save to have occurred.
NOTE: The programming mode may be exited at
any time, by pressing the SETUP key. Pressing this
key will return the monitor to its normal operation.
All items changed and saved will come into effect
immediately. Any items changed, but not saved
will revert to the original programmed value.

66 6/05
OPERATION IS628
NOTE: If a discrepancy occurs and digits must be changed, follow STEPS 1 and 2 to enter the programming mode
and proceed as follows:
Press the OK key and the flashing arrow becomes solid. The least significant digit of the displayed value will be
blinking.
This value can be changed by pressing either the UP or DOWN arrow keys.
Once this digit is correct, press the SELECT key and the blinking digit will move to the next significant digit, where
the process can be repeated.
The monitor limits the entry of pulses per mile or kilometer to a minimum of 500 PPM (310 PPKM), and to a maximum
of 500,000 PPM (310,686 PPKM).
KEY Action Flashing Digit Display Value
Press The UP Key Right Most Digit 203 1, 2032, 2033
Press The SELECT Key Second Digit From Right 20 33
Press The DOWN Key Second Digit From Right 20 23, 2013, 2003, 2093, 2083
Press The SELECT Key Twice Left Most Digit 2083
Press The DOWN Key Left Most Digit 1083, 0500 (Min. Value), 9500, 8500
To reset the counter, press the UP and
DOWN arrow keys at the same time and hold
them down for a short period of time to clear
the data. The CLEAR? icon will be displayed
and the monitor will beep several times.
When the data is actually cleared, the monitor
will emit a long beep, and the total area is
reset to zeros.
After the long beep, the
previous recorded total area is not retrievable.
Once cleared, the user may not choose to
exit programming mode without saving as
described in STEP 4.
STEP 4
To exit and save, press and hold the OK key.
The monitor will emit several short beeps
and SAVE? icon is turned on. After a short
time a long beep is heard, and the lower LCD
will display the word “DONE”. Release the
OK key. If the OK key is released BEFORE
the word “DONE” is displayed, the changes
WILL NOT BE SAVED. The word “DONE”
MUST be displayed in order for the save to
have occurred.
NOTE: The programming mode may be exited at
any time, by pressing the SETUP key. Pressing this
key will return the monitor to its normal operation.
All items changed and saved will come into effect
immediately. Any items changed, but not saved will
revert to the original programmed value.
PROGRAMMING - Clearing Total Area
NOTE: Clearing the total area counter will also
clear the field area counter.
STEP 1To enter the programming mode, press and
hold the SETUP key. The monitor will emit
several short beeps followed by a long
beep. On the lower LCD, the SETUP icon
turns on and the arrow head icon will flash,
indicating that the user can select an item to
program.
NOTE: The monitor must be in a programmable
function (row spacing, units, speed, volume or
area) to enter setup. The monitor will not enter
setup in seed population or seed spacing.
STEP 2Press the UP or DOWN arrow keys to move
the flashing arrow to TOTAL AREA. As the
arrow icon moves, the lower LCD will display
the current setting of the item selected.
STEP 3Press the OK key and the flashing arrow
becomes solid and the audible alarm will
sound.
The lower LCD will display the total area
and the ACRE (or Ha) icon turns on.
With the flashing arrow on TOTAL AREA,
press the OK key.

67 6/05
OPERATION IS628
The four possible data communication bus errors
are:
LCD Display Error Condition
SYS HI The data communication
lead (green) has been
shorted to the power lead
(white).
SYS LO The data communication
lead (green) has been
shorted to the ground lead
(black).
SYS EC An internal error has been
detected.
COP Cycled power ON/OFF to
quickly.
2. Under Flow Alarms - If the seed rate for one or
more rows is less than 55% of the calculated
average, the corresponding 60% segment will stay
on, the corresponding row number starts flashing
and the alarm sounds. Pushing the OK key to
acknowledge the warning will turn the alarm off.
The 60% segment of the bar graph remains on and
the row number continues to flash until the alarm
condition is corrected.
NOTE: All alarms present within a short time before
planting stops are frozen on the screen and the text
LOW or FAIL will display on the LCD. If the under
flow is between 0% and 10%, this warrants a “FAIL”
condition. If the under flow is between 10% and
55%, a “LOW” condition is generated. If multiple
rows have an under flow condition, “FAIL” will
display if any one or more rows is between 0% and
10%. This allows the user to identify and fix the
problem rows.
NOTE: This warning will not trigger unless a
minimum time of continuous planting has passed.
NOTE: If all the rows show a seed rate of zero, the
condition will not generate an alarm. It will be
assumed the planter has stopped. The row numbers
and the bottom 60% segment will remain on for all
selected rows.
3. Multiple Alarms - If more than one alarm condition
occurs at the same time, pushing the OK key will
acknowledge all alarms that are currently displayed.
For example, if one row on the front and one row on
the rear are alarming, pushing the OK key will only
acknowledge one of them. However, if there are
two alarms on the front, both alarms would be
acknowledged with one push of the OK key.
AREA COUNTER/SPEEDOMETER MODE
If the monitor is installed with only a radar distance
sensor (no seed tubes attached), the monitor becomes
a speedometer. If (a) the monitor is connected to a
radar distance sensor, (b) the signal cable from the
back of the console is connected to a sensing switch
(Part No. G1K249 Acre Counter Switch Kit) instead of
the seed tubes and (c) the implement width in feet (or
meters) is programmed into the monitor, the monitor will
function as an area counter.
The seed spacing and seed population functions are
not available in this mode. If the monitor is powered
down, the seed tubes connected and the monitor
powered up, the monitor will again show seed population
and seed spacing in inches or centimeters. Row spacing
reverts back to its programmed setting.
WARNINGS AND ALARMS
1. System Alarms - A system alarm is activated
when the monitor detects a faulty sensor or one of
several other communication faults.
The corresponding row number starts flashing and
the audible alarm sounds. All segments on the
corresponding bar graph are turned off.
Pushing
the OK key to acknowledge the warning will turn the
alarm off. The row number will continue to flash until
the alarm condition is removed. If the monitor
detects a faulty sensor and there is no planting
activity present, the monitor will scroll “CHECK
CONNECTION”.
If the distance sensor is detected as faulty, the
monitor will display either “PICKUP” or “RADAR”,
depending on the type of sensor installed, and the
audible alarm will sound. The user can push the OK
key to acknowledge the alarm. When the distance
sensor is faulty, the monitor will change to a bar
graph only mode where the rows are still displayed
relative to each other. No area related information
(speed, field area, total area, seed spacing or seed
population) will be accumulated or displayed.
If a rotation shaft sensor is faulty, “LSHAFT” or
“RSHAFT” will display. On Model 3800 planters,
“SHAFT1”, “SHAFT2”, “SHAFT3” or “SHAFT4” will
display.
Another type of system alarm occurs when the
monitor detects a data communication bus error.

68 6/05
OPERATION IS628
REPLACING A FAULTY SENSOR
NOTE: Stack-Mode Seed Sensors are identified by
a blue 3-pin connector. Replace Stack-Mode Seed
Sensors with like components only.
To replace a faulty sensor; (a) disconnect the faulty
sensor and check the monitor to be sure the correct
sensor was disconnected, (b)
turn the monitor off, (c)
after a few seconds, turn the monitor back on and (d)
plug in the replacement sensor. The monitor will chirp
twice to acknowledge the new sensor was learned and
saved.
To replace more than one faulty sensor, proceed as
stated above for
rear/front or left/right configurations
beginning with the lowest numbered row in the rear or
left section and continue to replace sensors in ascending
order. Then move on to the front or right section and
continue in ascending order. For
four section
configurations, begin with rear/left and continue to rear/
right, then front/left and ending with front/right.
If the monitor detects a faulty distance sensor, the lower
LCD will immediately move to the speed display, show
the word “PICKUP” or “RADAR” depending on the
distance sensor installed, and the alarm will sound.
NOTE: If the monitor is not turned off and then on,
the replacement sensor(s) will be ignored until the
next power on, at which point the sensors will be
randomly learned by the monitor.
4. Section Not Selected Warning - If the monitor
was programmed for two sections and only one is
currently selected for display (by pressing the
SELECT key), the icon of the disabled section will
flash for a period of 1 minute, then turn off at each
power up. If seed flow is sensed in the disabled
section, the icon for that section (front, left or right)
will begin to flash.
5. Seed Planting Stopped Warning - When the
monitor detects no seed flow on all rows, the
monitor will emit 3 short beeps to alert the user. This
warning will occur each time the planter is stopped,
each time the planter is raised at the end of a row or
if the mechanical drive fails while planting.
NOTE: This warning will not trigger unless a
minimum time of continuous planting has passed.
6. Seed Counting Sensor In Calibration Warning -
All seed counting sensors run a self-calibration
sequence on power up. While in calibration the
bottom segment of each corresponding bar graph will
flash if the monitor detects movement or planting
activity. If the monitor does not detect this, the message
“WAIT CALIBRATION” will be scrolled.
7. Seed Counting Sensor Too Dirty Warning - After
the seed counting sensors end their internal self-
calibration, the monitor may detect one or more
sensors are either too dirty or blocked. If the monitor
detects planting or movement, the corresponding bar
graph remains flashing. The monitor will display
“CLEAN SENSORS” on the top LCD if no movement
or planting is detected, prompting the user to clean
the tubes. If the tubes are dirty, they will still show
seed flow with less accuracy. If the tubes are blocked
the user will get an alarm as soon as planting starts.
The corresponding bar graph will remain flashing until
the problem is corrected and the monitor is powered
down and then powered back up.
8. Low Battery Warning - The monitor is constantly
monitoring its input voltage to quickly detect low
power conditions. If the monitor detects that the
input voltage has dropped below 11.0V, it will
display “LO SYS” on the lower LCD on the KPM II
Stack-Mode console, provided that the monitor
does not detect speed or planting.
NOTE: After the alarms have been acknowledged
and if the alarm condition is still present, the LCD
will continue to display the alarm condition.

69 6/05
OPERATION IS628
(MTR28e)
(MTR28c)
(MTR28c)
FIELD OPERATION
Press the ON/OFF key to turn the monitor
on.
Information regarding each section is dis-
played alternately every 5 seconds.
REAR/FRONT CONFIGURATION
(Without SMM Console Installed)
Press the SELECT key once to show
REAR section only. (Monitor sets cor- rect row spacing.)
Press the SELECT key a second time to
return to
each section being displayed
alternately every 5 seconds on KPM II
Stack-Mode console. (Monitor sets cor-
rect row spacing.)
Press the SELECT key a third time to
show REAR section only again.
REAR/FRONT CONFIGURATION
(With SMM Console Installed)
Press the SELECT key once to show
REAR section only on KPM II Stack-
Mode console. (Monitor sets correct row spacing.)
Press the SELECT key a second time to
show
FRONT section on SMM console
and REAR section on KPM II Stack-
Mode console. (Monitor sets correct row spacing.)
Press the SELECT key a third time to
show
REAR section only again.
FOUR SECTION CONFIGURATION
(With SMM Console Installed)
Press the SELECT key once to show
REAR and LEFT sections on KPM II
Stack-Mode console and REAR and
RIGHT sections on SMM console. (Moni- tor sets correct row spacing.)
Press the SELECT key a second time to
return to all four sections,
alternating
right front and right rear on SMM con-
sole and alternating left front and left rear
on KPM II Stack-Mode console. (Moni- tor sets correct row spacing.)
Press the SELECT key a third time to
show
REAR and LEFT sections on KPM
II Stack-Mode console and REAR and
RIGHT sections on SMM console again.
NOTE: SELECT key has no function when only a
single section is being used.
At power up, the lower LCD will show speed (MPH or KM/H).
(MTR29g/MTR29b/MTR29a/MTR29c/MTR29f/MTR29c/MTR29f)
Press the UP or DOWN arrow keys to move the flashing arrow on the lower LCD to change what is displayed on the lower LCD.
Press the shortcut keys SPEED, SEED POPULA-
TION/SEED SPACING or AREA FIELD/TOTAL for
direct access to these displays.
(MTR29c/MTR29d/MTR29b/MTR29c)
Press the SEED POPULATION/SEED SPACING or
AREA FIELD/TOTAL keys to alternate between the
two functions assigned to that key.
Press the SEED POPULATION/SEED
SPACING key to choose average seed
spacing/population per acre.
Press the SCAN key to display indi-
vidual rows starting at row 1.
Press the SCAN key again to lock on
current row.
Press the SCAN key again to resume
scrolling.
Use the UP or DOWN arrow keys to
move to a particular row.
Press the SEED POPULATION/SEED
SPACING key to go back to planter
average.
(MTR28c)
Rev. 4/06

70 6/05
OPERATION IS628
CLEARING FIELD AREA
(MTR29n/MTR28b)
To reset the counter, press the UP or
DOWN arrow keys to move the arrow
in the lower display to FIELD AREA.
Press the UP and DOWN arrow keys
at the same time and hold them down
for a short period of time to clear the
data. The CLEAR? icon will be
displayed and the monitor will beep
several times. When the data is actually
cleared, the monitor will emit a long
beep, and the field area is reset to
zero.
After the long beep, the previous
field area recorded is not retrievable.
NOTE: Clearing the field area counter will not clear
the total area counter. See “Programming-Clearing
Total Area” for clearing total area.
Press the OK key to silence alarms. See
“Warnings And Alarms”.

71 6/05
OPERATION IS628
PROGRAMMING/CONNECTING SMM CONSOLE,
SHAFT ROTATION SENSORS, SEED TUBES AND/
OR RADAR/MAGNETIC DISTANCE SENSORS
STEP 1All sensors (including the seed tubes w/
sensors, radar, magnetic distance, SMM
console and shaft rotation sensors) must be
unplugged from the harness and/or console
and the monitor must be off.
NOTE: If the monitor detects a radar sensor but no
seed tubes at power up, it will automatically go into
AREA COUNT mode. See “Area Counter/
Speedometer Mode”.
NOTE: Disconnect magnetic distance sensor
between MDS adapter and planter harness. DO
NOT disconnect between MDS and MDS adapter.
01189910
MDS Adapter
MDS
01189909
MDS Adapter
Harness
STEP 2Press the ON key. The monitor automatically enters the setup procedure. Monitor will scroll “NO SENSOR” on top LCD of KPM II Stack- Mode console.
STEP 3The monitor automatically defaults to rear/
front. Press the SELECT key once for left/
right and twice for four sections (front right/
front left/rear right/rear left). The selected
display will be solid and the configuration not
currently selected will be flashing.
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
TOTAL
UNITS
SPEED
VOLUME
SCAN
SEED
SEED
FIELD
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP FRONT
SETUP
REAR(LEFT) (RIGHT)
Flashing Flashing
® KPM II

12060211
® SMM

72 6/05
OPERATION IS628
NOTE: Model 3000, 3110, 3120, 3140, 3200, 3400,
3500, 3600, 3650 and 3700 (16 row) planters select
the rear/front configuration. Model 3700 (24/36
row) and Model 3800 planters select left/right
configuration.
12060211
® SMM
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
TOTAL
UNITS
SPEED
VOLUME
SCAN
SEED
SEED
FIELD
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
® KPM II

SETUP LEFT RIGHT(FRONT) (REAR)
Flashing Flashing
NOTE: SMM console may not be applicable to all
models.
STEP 4Press and hold the OK key to confirm selection. The upper display will alternate between “NEW” and “SYS?”.
The alarm will sound four short beeps
followed by one long beep. At this point your
selection has been saved and row numbers
will appear flashing on the upper display of
the KPM II.
ON
AREA
OFFEXIT
ENTER
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP FRONT
SETUP
REAR(LEFT) (RIGHT)
FLASHING FLASHING
OK
® KPM II

12060211
® SMM
NOTE: SMM console may not be applicable to all
models.

73 6/05
OPERATION IS628
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP FRONT
SETUP
REAR(LEFT) (RIGHT)
FLASHING FLASHING
® KPM II

12060211
® SMM
NOTE: SMM console may not be applicable to all
models.
NOTE: Illustrated using rear/front configuration.
The KPM II Stack-Mode console shows LEFT in the
left/right configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR LEFT in the
four sections configuration.
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
12060211
® SMM
® KPM II

SETUP
1
REAR
12111098765432 131415161718
FRONT
FLASHING
STEP 5(If Applicable) Connect SMM console into
junction Y-harness which was installed
between the KPM II Stack-Mode console
and the primary harness. The SMM console
will show a lighted screen and KPM will show
on the lower LCD.

74 6/05
OPERATION IS628
STEP 6If the monitor system includes shaft rotation
sensors, these should be installed at this
time. Plug in the L.H. shaft first, then the R.H.
shaft. L.H. and R.H. is determined by facing
in the direction the machine will travel when
in use.
“LSHAFT” or “SHAFT 1” will display on the
lower LCD when the first shaft rotation sensor
is installed. “RSHAFT” or “SHAFT 2” will
display when the second shaft rotation sensor
is installed.
NOTE:
Illustrated using rear/front
configuration. The KPM II Stack-Mode
console shows LEFT in the left/right
configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR
LEFT in the four sections configuration.
01189906
NOTE: SMM console may not be applicable to all models.
MODEL 3800 PLANTERS - The first shaft
rotation sensor installed will be assigned to
the rows on the outer L.H. half of the planter
and the second shaft rotation sensor
connected will be assigned to the rows on the
inner L.H. half of the planter.
“SHAFT 1” will display on the lower LCD
when the first shaft rotation sensor is installed.
“SHAFT 2” will display when the second
shaft rotation sensor is installed. “SHAFT 3”
will display on the lower LCD when the third
shaft rotation sensor is installed on the inner
R.H. half of the planter. “SHAFT 4” will display
when the fourth shaft rotation sensor is
installed on the outer R.H. half of the planter.
12060211
® SMM
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
SETUP
REAR
1
REAR
1211109876543(2 13 14 15 16 17 18)
(FRONT)
FLASHING
® KPM II

75 6/05
OPERATION IS628
STEP 7Determine which row you want as number
one and plug the seed tube w/sensor into the
harness.
Continue plugging in sensors along with
shaft rotation sensors if so equipped. Row 1
first, row 2 second and so on up to 18 rows.
When a sensor is plugged in, the
corresponding row number on the upper
LCD display will stay solid, the monitor will
chirp twice and a red LED (Light Emitting
Diode) on the seed tube sensor will turn on
for approximately 30 seconds to show
connection is made.
STEP 6(Continued)
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP REAR
121110987654321(13 14 15 16 17 18)
(FRONT)
FLASHING
SETUP
REAR
® KPM II

12060211
® SMM
(METR55b)
Red LED
Blue Connector
NOTE: Illustrated using rear/front
configuration. The KPM II Stack-Mode
console shows LEFT in the left/right
configuration, REAR in the rear/front
configuration and REAR LEFT/FRONT
LEFT in the four sections configuration.

76 6/05
OPERATION IS628
STEP 7(Continued)
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
1
SETUP
ROW REAR
REAR
1211109876543(2 13 14 15 16 17 18)
(FRONT)
FLASHING
Row Waiting To
Be Connected
®
Row Installed
KPM II

12060211
® SMM

77 6/05
OPERATION IS628
STEP 8When all the seed tubes for the current section
(rear/front, left/right or four section) are
installed,
check to be sure the upper LCD on
the KPM II Stack-Mode console displays
solid numbers for the number of seed tubes connected.
Press and hold the OK key to
save the setup for the current section. The
SAVE? icon will display followed by
continuous short beeps indicating the monitor
is preparing to save. The installer has 5
seconds to decide to save the current
configuration. During this time, four short
beeps will sound followed by a long beep and
the SAVE? icon will turn off and the word
“DONE” shows on the screen. The monitor
will continue to the second section installation
(If Applicable).
NOTE:
Illustrated using rear/front
configuration. The KPM II Stack-Mode
console shows LEFT in the left/right
configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR
LEFT in the four sections configuration.
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP REAR SAVE?
SAVE?SETUP
REAR
121110987654321
(13 14 15 16 17 18)
(FRONT)
ROW
FLASHING
Row Waiting To
Be Connected
® KPM II

12060211
® SMM

78 6/05
OPERATION IS628
STEP 8(Continued)
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP FRONT
SETUP
REAR
REAR
121110987654321
® KPM II

12060211
® SMM
NOTE: SMM console may not be applicable to all
models.

79 6/05
OPERATION IS628
STEP 9Follow STEPS 6, 7 and 8 to install the second,
third and fourth sections. If no seed tubes are
installed on additional sections, press and
hold the OK key. The word “DONE” will
appear on upper display. The alarm will
sound four short beeps followed by one long
beep and the SAVE? icon turns off. The
monitor has exited the setup mode. When
you release the OK key the upper display will
scroll “WAITING CALIBRATION”. The lower
display will show “GNDSPD” and the alarm
will sound continually until the distance sensor
is connected. See STEP 10.
NOTE: The SMM console LCD remains
blank (except the backlighted screen) until
the entire system is saved.
NOTE:
Illustrated using rear/front
configuration. The KPM II Stack-Mode
console shows LEFT in the left/right
configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR
LEFT in the four sections configuration.
The SMM console shows RIGHT in the
left/right configuration, FRONT in the
front/rear configuration and FRONT
RIGHT/REAR RIGHT in four sections
configuration.
NOTE: SMM console may not be applicable to all
models.
12060212
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
ROWFRONT
®
SMM
SETUP FRONT
12111098765432(1 13 14 15 16 17 18)
FLASHING
®
Row Waiting To
Be Connected
KPM II

80 6/05
OPERATION IS628
STEP 9(Continued)
NOTE: SMM console may not be applicable to all
models.
NOTE: SMM console may not be applicable to all models.
12060213
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
ROW FRONT
Row Installed
®
SMM
SETUP FRONT
1211109876543(21 131415161718)
FLASHING
®
Row Waiting To
Be Connected
KPM II

ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP.
FIELD
SELECT SPEED SCAN
SAVE?SETUP
ROW FRONT
12060214
®
SMM
SETUP
1110987654321
FRONT SAVE?
(12 13 14 15 16 17 18)
FLASHING
Rows Installed
®
Row Waiting To
Be Connected
KPM II

81 6/05
OPERATION IS628
STEP 10With the lower display showing “GNDSPD”,
connect the distance sensor. The monitor
will display “PICKUP” if a
magnetic distance
sensor is connected or “RADAR” if a radar
distance sensor is installed. Only one distance sensor can be connected at a time.
NOTE:
Illustrated using rear/front
configuration. The KPM II Stack-Mode
console shows LEFT in the left/right
configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR
LEFT in the four sections configuration.
The SMM console shows RIGHT in the
left/right configuration, FRONT in the rear/
front configuration and FRONT RIGHT/
REAR RIGHT in four sections
configuration.
NOTE: To connect the radar distance sensor, install
the 10" monitor/radar adapter between the console
and radar distance sensor to adapt the monitor
system to various tractor radar systems. DO NOT
CONNECT 10" MONITOR/RADAR ADAPTER PRIOR
TO THIS STEP. STEP 9(Continued)
12060215
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP
FRONT
®
SMM
SETUP FRONT
1110987654321 (1213 14 15 16 17 18)
FLASHING
® KPM II

82 6/05
OPERATION IS628
NOTE: To reprogram the system to monitor more
or less rows (up to the maximum of 18 per section,
72 total in four section configuration), all sensors
must be unplugged, followed by the complete setup
procedure.
NOTE: Individual seed tubes may be unplugged for
special situations. An alarm will sound which can
be silenced by touching the OK key. The monitor
will recognize the seed tube(s) when reconnected. STEP 10(Continued)
NOTE: SMM console may not be applicable to all
models.
NOTE: SMM console may not be applicable to all models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
REAR
12060216
®
SMM
®
120
110
100
90
80
70
60
% 1110987654321
12
REAR
120
110
100
90
80
70
60
% 1110987654321
FRONT
KPM II

ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
POPULATION
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
MPH
120
110
100
90
80
70
60
% 1110987654321
12060217
®
SMM
®
12
REAR
120
110
100
90
80
70
60
% 1110987654321
FRONT
KPM II

83 6/05
OPERATION IS628
ROW-BY-ROW ALARM LEVEL SETTING
(Requires Version V2.05 Or Higher Software -
KPM II Stack-Mode Monitors Only)
This feature allows the audio alarm to be disabled on
selected rows in applications such as planting seed corn.
NOTE: The system should be programmed to monitor
all planter rows prior to performing these steps.
NOTE:
Illustrated using rear/front configuration.
The KPM II Stack-Mode console shows LEFT in the
left/right configuration, REAR in the rear/front
configuration and FRONT LEFT/REAR LEFT in the
four sections configuration. The SMM console
shows RIGHT in the left/right configuration, FRONT
in the rear/front configuration and FRONT RIGHT/
REAR RIGHT in four sections configuration.
STEP 1Enter the programming mode by pressing and
holding the SETUP key. The monitor will emit
several short beeps, followed by a long beep.
On the lower LCD, the SETUP icon will turn on
and the arrow head icon will flash, indicating
the user can select an item to program.
NOTE: The monitor must be in a programmable
function (row spacing, unit, speed, volume or area)
to enter setup. The monitor will not enter setup in
seed population or seed spacing.
STEP 2Press the UP or DOWN arrow keys to move
the flashing arrow to SEED POPULATION. As
the arrow icon moves, the lower LCD will
display the current setting of each item selected.
12060218
NOTE: SMM console may not be applicable to all
models.
ON
AREA
OFFEXIT
ENTER
OK
CLEAR
SETUP
ROW
SPACING
TOTAL
AREA
UNITS
SPEED
VOLUME
SCAN
SEED
SPACING
FIELD
AREA
SPACING
TOTAL
SEED
POP. FIELD
SELECT SPEED SCAN
SETUP REAR
121110987654321 (13 14 15 16 17 18)
ROW
SETUP
REAR
SEED
POPULATION
SMM
®
®
SETUP
21
FRONT
(1211109876543 13 14 15 16 17 18)
120
110
100
90
80
70
60
%
120 110 100
90
80
70
60
%
KPM II

84 6/05
OPERATION IS628
NOTE:
See “Programming - Row
Spacing” for programming
applicable row spacing.
STEP 3Press the OK key. Row number starts
flashing.
STEP 4Arrow UP or DOWN to desired row.
STEP 5Press SELECT key. “AVG” starts flashing.
STEP 6Arrow UP or DOWN to choose one of the
following options.
HIGH - For Early Alarm (70%)
AVG - For Standard Alarm Setting (55%)
LOW - For Failed Alarm Only (25%)
OFF - To Disable Row Alarm
STEP 7Press and hold the OK key to save alarm
setting. There will be four short beeps, one
long beep and the word “DONE” will appear
when the save is completed.
STEP 8Repeat STEPS 3 through 7 for each row on
which you wish to adjust the alarm setting.
STEP 9When finished, press the SETUP key to exit
setup mode.
NOTE: The programming mode may be exited at
any time by pressing the SETUP key. Pressing this
key will return the monitor to its normal operation.
All items changed and saved will come into effect
immediately. Any items changed, but not saved will
revert to the original programmed value.
NOTE: Repeat STEPS 3 through 7 to change seed
monitor back to the original settings when special
row-by-row alarm level settings are no longer
required.

85 6/05
OPERATION IS628
MODEL 3140 3 Pt. Mounted
Stack Folding
(Mechanical Seed Metering) 8 Row 12 Row 16 Row
KPM I Monitor Package 700-05097 700-05098 700-05099
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05100 700-05101 700-05102
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05103 700-05104 700-05105
CONTENTS LISTINGS IS628
MODEL 3000 Pull Type
(Mechanical Seed Metering) 4 Row 6 Row 8 Row
KPM I Monitor Package 700-05088 700-05089 700-05090
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05091 700-05092 700-05093
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05094 700-05095 700-05096
Interplant
®
Monitor Package 700-05114 700-05115 700-05116
MODEL 3110 3 Pt. Mounted
Rigid Frame
(Mechanical Seed Metering) 6 Row 8 Row
KPM I Monitor Package 700-05089 700-05090
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05092 700-05093
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05095 700-05096
MODEL 3120 3 Pt. Mounted
Vertical Folding
(Mechanical Seed Metering) 8 Row 12 Row
KPM I Monitor Package 700-05090 700-05108
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05120 700-05121
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05119 700-05122
Rev. 6/06

86 6/05
OPERATION IS628
MODEL 3500 Twin-Line
®
(Mechanical Seed Metering) 6 Row 8 Row
KPM I Monitor Package 700-05089 700-05090
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05092 700-05093
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05095 700-05096
Interplant
®
Monitor Package 700-05115 700-05116
CONTENTS LISTINGS IS628
MODEL 3200 Flex Econo-Fold
®
(Mechanical Seed Metering) 8 Row 12 Row
KPM I Monitor Package 700-05090 700-05108
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05124 700-05110
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05119 700-05122
MODEL 3400 Twin-Line
®
(Mechanical Seed Metering) 12 Row
KPM I Monitor Package 700-05108
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05130
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05131
Interplant
®
Monitor Package 700-05117
Rev. 6/06

87 6/05
OPERATION IS628
MODEL 3800 Forward Folding
(Mechanical Seed Metering) 24 Row 32 Row 36 Row
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05136 700-05138 700-05140
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05137 700-05139 700-05141
CONTENTS LISTINGS IS628
MODEL 3600 Twin-Line
®
(Mechanical Seed Metering) 8 Row 12 Row 16 Row
KPM I Monitor Package 700-05090 700-05108 700-05109
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05124 700-05110 700-05111
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05119 700-05112 700-05113
Interplant
®
Monitor Package 700-05116 700-05117 700-05118
MODEL 3700 Front Folding
(Mechanical Seed Metering) 16 Row 24 Row 36 Row
KPM I Monitor Package 700-05125 700-05128 700-05129
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05126 700-05132 700-05134
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05127 700-05133 700-05135
MODEL 3650 Twin-Line
®
(Mechanical Seed Metering) 12 Row 16 Row
KPM I Monitor Package 700-05108 700-05109
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05110 700-05111
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05112 700-05113
Interplant
®
Monitor Package 700-05117 700-05118
Rev. 6/06

88 6/05
OPERATION IS628
MODEL 3140 3 Pt. Mounted
Stack Folding
(EdgeVac
®
Seed Metering) 8 Row 12 Row 16 Row
KPM I Monitor Package 700-05218 700-05219 700-05220
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05221 700-05222 700-05223
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05224 700-05225 700-05226
MODEL 3000 Pull Type
(EdgeVac
®
Seed Metering) 4 Row 6 Row 8 Row
KPM I Monitor Package 700-05209 700-05210 700-05211
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05212 700-05213 700-05214
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05215 700-05216 700-05217
Interplant
®
Monitor Package 700-05252 700-05253 700-05254
MODEL 3110 3 Pt. Mounted
Rigid Frame
(EdgeVac
®
Seed Metering) 6 Row 8 Row
KPM I Monitor Package 700-05210 700-05211
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05213 700-05214
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05216 700-05217
Rev. 6/06

89 6/05
OPERATION IS628
MODEL 3500 Twin-Line
®
(EdgeVac
®
Seed Metering) 6 Row 8 Row
KPM I Monitor Package 700-05210 700-05211
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05213 700-05214
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05216 700-05217
Interplant
®
Monitor Package 700-05253 700-05254
MODEL 3200 Flex Econo-Fold
®
(EdgeVac
®
Seed Metering) 8 Row 12 Row
KPM I Monitor Package 700-05211 700-05227
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05234 700-05229
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05233 700-05231
MODEL 3400 Twin-Line
®
(EdgeVac
®
Seed Metering) 12 Row
KPM I Monitor Package 700-05227
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05244
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05245
Interplant
®
Monitor Package 700-05255
Rev. 6/06

90 6/05
OPERATION IS628
MODEL 3800 Forward Folding
(EdgeVac
®
Seed Metering) 24 Row 32 Row 36 Row
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05246 700-05248 700-05250
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05247 700-05249 700-05251
MODEL 3600 Twin-Line
®
(EdgeVac
®
Seed Metering) 8 Row 12 Row 16 Row
KPM I Monitor Package 700-05211 700-05227 700-05228
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05234 700-05229 700-05230
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05233 700-05231 700-05232
Interplant
®
Monitor Package 700-05254 700-05255 700-05256
MODEL 3700 Front Folding
(EdgeVac
®
Seed Metering) 16 Row 24 Row 36 Row
KPM I Monitor Package 700-05235 700-05236 700-05237
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05238 700-05239 700-05240
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05241 700-05242 700-05243
MODEL 3650 Twin-Line
®
(EdgeVac
®
Seed Metering) 12 Row 16 Row
KPM I Monitor Package 700-05227 700-05228
KPM II Stack-Mode Monitor Package
Magnetic Distance Sensor 700-05229 700-05230
KPM II Stack-Mode Monitor Package
Radar Distance Sensor 700-05231 700-05232
Interplant
®
Monitor Package 700-05255 700-05256
Rev. 6/06

91 6/05
OPERATION IS628CONTENTS LISTINGS IS628
4 ROW SIZES (Mechanical Seed Metering)
KPM I Monitor Package, 4 Row - 700-05088
Model 3000 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(1)A8021 Planter Harness W/Dust Caps (4 Row)
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
(4)A10901 Seed Tube W/Sensor
KPM II Monitor Package, 4 Row - 700-05091
(With Magnetic Distance Sensor)
Model 3000 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A8021 Planter Harness W/Dust Caps (4 Row)
(4)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 4 Row - 700-05094
(With Radar Distance Sensor)
Model 3000 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A8021 Planter Harness W/Dust Caps (4 Row)
(4)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
Rev. 6/06
4 ROW SIZES (EdgeVac
®
Seed Metering)
KPM I Monitor Package, 4 Row - 700-05209
Model 3000 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(1)A8021 Planter Harness W/Dust Caps (4 Row)
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
(4)A10142 Seed Tube W/Sensor
KPM II Monitor Package, 4 Row - 700-05212
(With Magnetic Distance Sensor)
Model 3000 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A8021 Planter Harness W/Dust Caps (4 Row)
(4)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 4 Row - 700-05215
(With Radar Distance Sensor)
Model 3000 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A8021 Planter Harness W/Dust Caps (4 Row)
(4)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps

92 6/05
OPERATION IS628
6 ROW SIZES (Mechanical Seed Metering)
KPM I Monitor Package, 6 Row - 700-05089
Models 3000, 3110 Rigid Frame And 3500 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(6)A10901 Seed Tube W/Sensor
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 6 Row - 700-05092
(With Magnetic Distance Sensor)
Models 3000, 3110 Rigid Frame And 3500 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(6)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 6 Row - 700-05095
(With Radar Distance Sensor)
Models 3000, 3110 Rigid Frame And 3500 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(6)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
6 ROW SIZES (EdgeVac
®
Seed Metering)
KPM I Monitor Package, 6 Row - 700-05210
Models 3000, 3110 Rigid Frame And 3500 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(6)A10142 Seed Tube W/Sensor
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 6 Row - 700-05213
(With Magnetic Distance Sensor)
Models 3000, 3110 Rigid Frame And 3500 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(6)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 6 Row - 700-05216
(With Radar Distance Sensor)
Models 3000, 3110 Rigid Frame And 3500 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(6)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
Rev. 6/06

93 6/05
OPERATION IS628CONTENTS LISTINGS IS628
KPM II Monitor Package, 8 Row - 700-05093
(With Magnetic Distance Sensor)
Models 3000, 3110 Rigid Frame And 3500 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(8)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 8 Row - 700-05100
(With Magnetic Distance Sensor)
Model 3140 Stack Folding (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(8)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 8 Row - 700-05119
(With Radar Distance Sensor)
Models 3120 Vertical Folding, 3200 And 3600 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(8)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
8 ROW SIZES (Mechanical Seed Metering)
KPM I Monitor Package, 8 Row - 700-05090
Models 3000, 3110 Rigid Frame, 3120 Vertical Fold-
ing, 3200, 3500 And 3600 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1A10570 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(8)A10901 Seed Tube W/Sensor
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM I Monitor Package, 8 Row - 700-05097
Model 3140 Stack Folding
(1)IS628 Instructions
(1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(8)A10901 Seed Tube W/Sensor
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 8 Row - 700-05120
(With Magnetic Distance Sensor)
Model 3120 Vertical Folding (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(8)A10901 Seed Tube W/Sensor
(1)A5606 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 8 Row - 700-05124
(With Magnetic Distance Sensor)
Models 3200 And 3600 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(8)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
Rev. 6/06

94 6/05
OPERATION IS628
KPM II Monitor Package, 8 Row - 700-05096
(With Radar Distance Sensor)
Model 3110 Rigid Frame And 3500 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(8)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 8 Row - 700-05103
(With Radar Distance Sensor)
Model 3140 Stack Folding (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(8)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
8 ROW SIZES (EdgeVac
®
Seed Metering)
KPM I Monitor Package, 8 Row - 700-05211
Models 3000, 3110 Rigid Frame, 3200, 3500 And 3600 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1A10570 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter H arness W/Dust Caps (8 Row)
(8)A10142 Seed Tube W/Sensor
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM I Monitor Package, 8 Row - 700-05218
Model 3140 Stack Folding
(1)IS628 Instructions
(1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A8022 Planter H arness W/Dust Caps (6 Row)
(2)A8021 Planter H arness W/Dust Caps (4 Row)
(8)A10142 Seed Tube W/Sensor
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 8 Row - 700-05234
(With Magnetic Distance Sensor)
Models 3200 And 3600 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter H arness W/Dust Caps (8 Row)
(8)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 8 Row - 700-05214
(With Magnetic Distance Sensor)
Models 3000, 3110 Rigid Frame And 3500 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter H arness W/Dust Caps (8 Row)
(8)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
Rev. 6/06

95 6/05
OPERATION IS628CONTENTS LISTINGS IS628
Rev. 6/06
KPM II Monitor Package, 8 Row - 700-05221
(With Magnetic Distance Sensor)
Model 3140 Stack Folding (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(8)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 8 Row - 700-05233
(With Radar Distance Sensor)
Models 3200 And 3600 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(8)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 8 Row - 700-05217
(With Radar Distance Sensor)
Model 3110 Rigid Frame And 3500 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(8)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 8 Row - 700-05224
(With Radar Distance Sensor)
Model 3140 Stack Folding (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(8)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps

96 6/05
OPERATION IS628
KPM II Monitor Package, 12 Row - 700-05130
(With Magnetic Distance Sensor)
Model 3400 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 12 Row - 700-05101
(With Magnetic Distance Sensor)
Models 3140 Stack Folding
(1)IS628 Instructions
(1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(12)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 12 Row - 700-05122
(With Radar Distance Sensor)
Models 3120 Vertical Folding And 3200 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
12 ROW SIZES (Mechanical Seed Metering)
KPM I Monitor Package, 12 Row - 700-05098
Model 3140 Stack Folding (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Exension Harness W/Female
Connectors, 15'
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(12)A10901 Seed Tube W/Sensor
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM I Monitor Package, 12 Row - 700-05108
Models 3120 Vertical Folding, 3200, 3400, 3600
And 3650
(1)IS628 Instructions
(1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10901 Seed Tube W/Sensor
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 12 Row - 700-05121
(With Magnetic Distance Sensor)
Model 3120 Vertical Folding (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10901 Seed Tube W/Sensor
(1)A5606 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 12 Row - 700-05110
(With Magnetic Distance Sensor)
Models 3200, 3600 And 3650 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
Rev. 6/06

97 6/05
OPERATION IS628CONTENTS LISTINGS IS628
KPM II Monitor Package, 12 Row - 700-05104
(With Radar Distance Sensor)
Model 3140 Stack Folding
1)IS628 Instructions
(1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(12)A10901 Seed Tube W/Sensor
(1)A7858 Radar Gun
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A8026 Radar Sensor
KPM II Monitor Package, 12 Row - 700-05131
(With Radar Distance Sensor)
Model 3400 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8026 Radar Pipe/Mounting Bracket Package
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 12 Row - 700-05112
(With Radar Distance Sensor)
Models 3600 And 3650 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
Rev. 6/06
12 ROW SIZES (EdgeVac
®
Seed Metering)
KPM I Monitor Package, 12 Row - 700-05219
Model 3140 Stack Folding (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Exension Harness W/Female
Connectors, 15'
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(12)A10142 Seed Tube W/Sensor
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM I Monitor Package, 12 Row - 700-05227
Models 3200, 3400, 3600 And 3650
(1)IS628 Instructions
(1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10142 Seed Tube W/Sensor
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 12 Row - 700-05229
(With Magnetic Distance Sensor)
Models 3200, 3600 And 3650 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps

98 6/05
OPERATION IS628
KPM II Monitor Package, 12 Row - 700-05244
(With Magnetic Distance Sensor)
Model 3400 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 12 Row - 700-05222
(With Magnetic Distance Sensor)
Models 3140 Stack Folding
(1)IS628 Instructions
(1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(12)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 12 Row - 700-05225
(With Radar Distance Sensor)
Model 3140 Stack Folding
(1)IS628 Instructions
(1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A7850 Planter Harness W/Dust Caps (8 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(12)A10142 Seed Tube W/Sensor
(1)A7858 Radar Gun
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A8026 Radar Sensor
KPM II Monitor Package, 12 Row - 700-05245
(With Radar Distance Sensor)
Model 3400 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8026 Radar Pipe/Mounting Bracket Package
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 12 Row - 700-05231
(With Radar Distance Sensor)
Models 3200, 3600 And 3650 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(12)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
Rev. 6/06

99 6/05
OPERATION IS628
KPM II Monitor Package, 16 Row - 700-05126
(With Magnetic Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7850 Planter Harness W/Dust Caps (8 Row)
(16)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 16 Row - 700-05102
(With Magnetic Distance Sensor)
Model 3140 Stack Folding
(1)IS628 Instructions
(1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(16)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 16 Row - 700-05113
(With Radar Distance Sensor)
Models 3600 And 3650 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7852 Planter Harness W/Dust Caps (16 Row)
(16)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
CONTENTS LISTINGS IS628
16 ROW SIZES (Mechanical Seed Metering)
KPM I Monitor Package, 16 Row - 700-05125
Model 3700 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A7850 Planter Harness W/Dust Caps (8 Row)
(16)A10901 Seed Tube W/Sensor
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM I Monitor Package, 16 Row - 700-05099
Model 3140 Stack Folding
(1)IS628 Instructions
(1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(16)A10901 Seed Tube W/Sensor
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM I Monitor Package, 16 Row - 700-05109
Models 3600 And 3650
(1)IS628 Instructions
(1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(1)A7852 Planter Harness W/Dust Caps (16 Row)
(16)A10901 Seed Tube W/Sensor
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 16 Row - 700-05111
(With Magnetic Distance Sensor)
Models 3600 And 3650 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7852 Planter Harness W/Dust Caps (16 Row)
(16)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
Rev. 6/06

100 6/05
OPERATION IS628CONTENTS LISTINGS IS628
KPM II Monitor Package, 16 Row - 700-05127
(With Radar Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7850 Planter Harness W/Dust Caps (8 Row)
(16)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 16 Row - 700-05105
(With Radar Distance Sensor)
Model 3140 Stack Folding
(1)IS628 Instructions
(1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(16)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
Rev. 6/06
16 ROW SIZES (EdgeVac
®
Seed Metering)
KPM I Monitor Package, 16 Row - 700-05235
Model 3700
(1)IS628 Instructions
(1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A7850 Planter Harness W/Dust Caps (8 Row)
(16)A10142 Seed Tube W/Sensor
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM I Monitor Package, 16 Row - 700-05220
Model 3140 Stack Folding
(1)IS628 Instructions
(1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(16)A10142 Seed Tube W/Sensor
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM I Monitor Package, 16 Row - 700-05228
Models 3600 And 3650
(1)IS628 Instructions
(1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(1)A7852 Planter Harness W/Dust Caps (16 Row)
(16)A10142 Seed Tube W/Sensor
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 16 Row - 700-05230
(With Magnetic Distance Sensor)
Models 3600 And 3650 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7852 Planter Harness W/Dust Caps (16 Row)
(16)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps

101 6/05
OPERATION IS628
KPM II Monitor Package, 16 Row - 700-05238
(With Magnetic Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7850 Planter Harness W/Dust Caps (8 Row)
(16)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 16 Row - 700-05223
(With Magnetic Distance Sensor)
Model 3140 Stack Folding
(1)IS628 Instructions
(1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(16)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 16 Row - 700-05232
(With Radar Distance Sensor)
Models 3600 And 3650 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(1)A7852 Planter Harness W/Dust Caps (16 Row)
(16)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 16 Row - 700-05241
(With Radar Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7850 Planter Harness W/Dust Caps (8 Row)
(16)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 16 Row - 700-05226
(With Radar Distance Sensor)
Model 3140 Stack Folding
(1)IS628 Instructions
(1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7849 Extension Harness W/Female
Connectors, 15'
(1)A7851 Planter Harness W/Dust Caps (12 Row)
(2)A8021 Planter Harness W/Dust Caps (4 Row)
(16)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
Rev. 6/06

102 6/05
OPERATION IS628CONTENTS LISTINGS IS628
24 ROW SIZES (Mechanical Seed Metering)
KPM I Monitor Package, 24 Row - 700-05128
Model 3700 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A7851 Planter Harness W/Dust Caps (12 Row)
(24)A10901 Seed Tube W/Sensor
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 24 Row - 700-05132
(With Magnetic Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7851 Planter Harness W/Dust Caps (12 Row)
(24)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A9857 SMM Backlit Monitor
(1)A7853 Junction Y-Harness W/Dust Cap
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 24 Row - 700-05136
(With Magnetic Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7851 Planter Harness W/Dust Caps
(12 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(24)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(4)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap
KPM II Monitor Package, 24 Row - 700-05133
(With Radar Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7851 Planter Harness W/Dust Caps
(12 Row)
(24)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket
Package
(1)A9857 SMM Backlit Monitor
(1)A7853 Junction Y-Harness W/Dust Cap
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 24 Row - 700-05137
(With Radar Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7851 Planter Harness W/Dust Caps
(12 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(24)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket
Package
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(4)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap
Rev. 6/06

103 6/05
OPERATION IS628
24 ROW SIZES (EdgeVac
®
Seed Metering)
KPM I Monitor Package, 24 Row - 700-05236
Model 3700 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A7851 Planter Harness W/Dust Caps (12 Row)
(24)A10142 Seed Tube W/Sensor
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 24 Row - 700-05239
(With Magnetic Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7851 Planter Harness W/Dust Caps (12 Row)
(24)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A9857 SMM Backlit Monitor
(1)A7853 Junction Y-Harness W/Dust Cap
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 24 Row - 700-05246
(With Magnetic Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7851 Planter Harness W/Dust Caps
(12 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(24)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(4)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap
KPM II Monitor Package, 24 Row - 700-05242
(With Radar Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7851 Planter Harness W/Dust Caps
(12 Row)
(24)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket
Package
(1)A9857 SMM Backlit Monitor
(1)A7853 Junction Y-Harness W/Dust Cap
(3)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 24 Row - 700-05247
(With Radar Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7851 Planter Harness W/Dust Caps
(12 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(24)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket
Package
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(4)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap
Rev. 6/06

104 6/05
OPERATION IS628CONTENTS LISTINGS IS628
32 ROW SIZE (Mechanical Seed Metering)
KPM II Monitor Package, 32 Row - 700-05138
(With Magnetic Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7852 Planter Harness W/Dust Caps (16 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(32)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(5)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap
KPM II Monitor Package, 32 Row - 700-05139
(With Radar Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7852 Planter Harness W/Dust Caps (16 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(32)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(5)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap
Rev. 6/06
32 ROW SIZE (EdgeVac
®
Seed Metering)
KPM II Monitor Package, 32 Row - 700-05248
(With Magnetic Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7852 Planter Harness W/Dust Caps (16 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(32)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(5)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap
KPM II Monitor Package, 32 Row - 700-05249
(With Radar Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7852 Planter Harness W/Dust Caps (16 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(32)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket Package
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(5)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap

105 6/05
OPERATION IS628
36 ROW SIZES (Mechanical Seed Metering)
KPM I Monitor Package, 36 Row - 700-05129
Model 3700 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A8050 Planter Harness W/Dust Caps (18 Row)
(36)A10901 Seed Tube W/Sensor
(4)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 36 Row - 700-05134
(With Magnetic Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A8050 Planter Harness W/Dust Caps (18 Row)
(36)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A9857 SMM Backlit Monitor
(1)A7853 Junction Y-Harness W/Dust Cap
(4)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 36 Row - 700-05140
(With Magnetic Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7852 Planter Harness W/Dust Caps
(16 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(36)A10901 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(5)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap
KPM II Monitor Package, 36 Row - 700-05135
(With Radar Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A8050 Planter Harness W/Dust Caps
(18 Row)
(36)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket
Package
(1)A9857 SMM Backlit Monitor
(1)A7853 Junction Y-Harness W/Dust Cap
(4)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 36 Row - 700-05141
(With Radar Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7852 Planter Harness W/Dust Caps
(16 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(36)A10901 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket
Package
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(5)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap
Rev. 6/06

106 6/05
OPERATION IS628CONTENTS LISTINGS IS628
Rev. 6/06
KPM II Monitor Package, 36 Row - 700-05243
(With Radar Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A8050 Planter Harness W/Dust Caps
(18 Row)
(36)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket
Package
(1)A9857 SMM Backlit Monitor
(1)A7853 Junction Y-Harness W/Dust Cap
(4)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 36 Row - 700-05251
(With Radar Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7852 Planter Harness W/Dust Caps
(16 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(36)A10142 Seed Tube W/Sensor
(1)A7858 Radar Sensor
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A8026 Radar Pipe/Mounting Bracket
Package
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(5)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap
36 ROW SIZES (EdgeVac
®
Seed Metering)
KPM I Monitor Package, 36 Row - 700-05237
Model 3700 (1)IS628 Instructions (1)IS448 Quick Reference Guide
(1)A10570 Backlit Console W/Fuse (1-36 Row)
(2)A8050 Planter Harness W/Dust Caps (18 Row)
(36)A10142 Seed Tube W/Sensor
(4)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 36 Row - 700-05240
(With Magnetic Distance Sensor)
Model 3700 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A8050 Planter Harness W/Dust Caps (18 Row)
(36)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(1)A8128 Drill Shaft Sensor Mounting Kit
(1)A8135 Drill Shaft Rotation Sensor Kit
(1)A9857 SMM Backlit Monitor
(1)A7853 Junction Y-Harness W/Dust Cap
(4)A8143 50 Pc. Pkg. (D1512) Tie Straps
KPM II Monitor Package, 36 Row - 700-05250
(With Magnetic Distance Sensor)
Model 3800 (1)IS628 Instructions (1)IS539 Quick Reference Guide
(1)A10575 Backlit Console W/Fuse (1-36 Row)
(2)A7852 Planter Harness W/Dust Caps
(16 Row)
(1)A8022 Planter Harness W/Dust Caps (6 Row)
(36)A10142 Seed Tube W/Sensor
(1)A6147 Sensor And Mounting Package
(1)A7859 MDS Adapter
(2)A8128 Drill Shaft Sensor Mounting Kit
(2)A8135 Drill Shaft Rotation Sensor Kit
(1)A9857 SMM Backlit Monitor
(1)A7849 Extension Harness W/Female
Connectors, 15'
(5)A8143 50 Pc. Pkg. (D1512) Tie Straps
(1)A7853 Junction Y-Harness W/Dust Cap

107 6/05
OPERATION IS628
INTERPLANT
®
MONITOR PACKAGES
(Mechanical Seed Metering)
Interplant
®
Monitor Package,
4 Row - 700-05114
Model 3000 (1)A8021 Planter Harness W/Dust Caps (4 Row)
(3)A10901 Seed Tube W/Sensor
(1)A7853 Junction Y-Harness W/Dust Cap
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
Interplant
®
Monitor Package,
6 Row - 700-05115
Models 3000 And 3500 (1)A8021 Planter Harness W/Dust Caps (4 Row)
(5)A10901 Seed Tube W/Sensor
(1)A7853 Junction Y-Harness W/Dust Cap
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
Interplant
®
Monitor Package,
8 Row - 700-05116
Models 3000, 3500 And 3600 (1)A8022 Planter Harness W/Dust Caps (6 Row)
(7)A10901 Seed Tube W/Sensor
(1)A7853 Junction Y-Harness W/Dust Cap
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
Interplant
®
Monitor Package,
12 Row - 700-05117
Models 3400, 3600 And 3650 (1)A7851 Planter Harness W/Dust Caps (12 Row)
(11)A10901 Seed Tube W/Sensor
(1)A7853 Junction Y-Harness W/Dust Cap
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
Interplant
®
Monitor Package,
16 Row - 700-05118
Models 3600 And 3650 (15)A10901 Seed Tube W/Sensor
(1)A7853 Junction Y-Harness W/Dust Cap
(1)A7852 Planter Harness W/Dust Caps (16 Row)
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
CONTENTS LISTINGS IS628
Rev. 6/06
INTERPLANT
®
MONITOR PACKAGES
(EdgeVac
®
Seed Metering)
Interplant
®
Monitor Package,
4 Row - 700-05252
Model 3000 (1)A8021 Planter Harness W/Dust Caps (4 Row)
(3)A10142 Seed Tube W/Sensor
(1)A7853 Junction Y-Harness W/Dust Cap
(1)A8143 50 Pc. Pkg. (D1512) Tie Straps
Interplant
®
Monitor Package,
6 Row - 700-05253
Models 3000 And 3500 (1)A8021 Planter Harness W/Dust Caps (4 Row)
(5)A10142 Seed Tube W/Sensor
(1)A7853 Junction Y-Harness W/Dust Cap
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
Interplant
®
Monitor Package,
8 Row - 700-05254
Models 3000, 3500 And 3600 (1)A8022 Planter Harness W/Dust Caps (6 Row)
(7)A10142 Seed Tube W/Sensor
(1)A7853 Junction Y-Harness W/Dust Cap
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
Interplant
®
Monitor Package,
12 Row - 700-05255
Models 3400, 3600 And 3650 (1)A7851 Planter Harness W/Dust Caps (12 Row)
(11)A10142 Seed Tube W/Sensor
(1)A7853 Junction Y-Harness W/Dust Cap
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps
Interplant
®
Monitor Package,
16 Row - 700-05256
Models 3600 And 3650 (15)A10142 Seed Tube W/Sensor
(1)A7853 Junction Y-Harness W/Dust Cap
(1)A7852 Planter Harness W/Dust Caps (16 Row)
(2)A8143 50 Pc. Pkg. (D1512) Tie Straps

108 6/05
OPERATION IS628
KINZE
®
, the KINZE
®
logo, Econo-Fold
®
, Twin-Line
®
, Interplant
®
and EdgeVac
®
are registered trademarks
of KINZE Manufacturing, Inc.
NOTES IS628